Page 38
4.3. Replacing Parts
For any spare parts that are required, please contact either your supplier or the manufacturer
directly. You will need the model name i.e. model number, the gas type, the type of control
and serial number.
Only approved parts should be used.
Ensure that the gas supply to the appliance has been isolated at the service tap before
proceeding.
Remove the burner assembly from the firebox as follows:-
1. Remove the front plate by removing the two retaining screws.
2. Disconnect the gas supply to the control valve under the burner assembly.
3. Remove the two burner assembly securing screws and withdraw the burner assembly
from the firebox.
4. Proceed to replacing parts as required.
4.3.1. Pilot Assembly Replacement
NOTE:
If any part of the pilot assembly becomes faulty then the whole pilot
assembly will need changing.
1. Remove the HT lead from the end of the
electrode.
2. Cut the cable tie wrap.
3.
Using M9 spanner undo the
thermocouple connection from behind
the control valve
4. Using M10 spanner undo the pilot feed
pipe nut at the pilot assembly.
5. Remove the pilot lint guard and undo the
pilot assembly securing screws and
withdraw the pilot assembly.
6. Refit in reverse order ensuring that the
lint guard is fitted.
4.3.2. Injector Replacement
1. Undo the compression nut at the injector
(Detail A).
2. Remove the two burner mounting
bracket securing nuts (Details B) and
separate the mounting bracket from the
base plate at the injector end of the
burner.
3. Unscrew the injector and replace with
new one.
4. Refit in reverse order ensuring that the
injector has been screwed in fully.
Injector
burner
burner mounting
bracket
B
B
A
base
plate
Figure 61