MAINTENANCE AND REPAIRS
REVISIONE: X51-1213 EN
30
MAGIDO GROUP S.r.l.
Trouble shooting
A number of possible inconveniences that may occur on the machine are listed below.
PROBLEM
CAUSE
CAUSE
SOLUTION
1- The machine does not start
Main power supply fuses have blown
Change
Bad connection between machine and
main power supply
Reset
Step down transformer fuse has blown
Change
2- The pump does not start
Timer has not been set
Set
Circuit breaker not engaged *
Engage
Lid not close properly
Close
3 – The heater does not heat
up
Fuses F1 have blown
Change
The thermostat is defective
Change
Heater element burnt out
Change
Weekly timer (optional) not set
Set
4 – The basket does not rotate
Excessive load
Decrease the weight
Load not uniformly distributed
Correct
The spray nozzles are clogged
Clean
Pump rotates in the wrong direction
Invert rotation
Filter is dirty or obstructed
Clean
Lower spray tube is not regulate
Set
Basket brake is defective
Control
5 – Incomplete wash
Wash time too short
Increase time
Wash solution too dirty
Change solutions
The spray nozzles are coggled
Clean
Filter is dirty or obstructed
Clean
Basket does not rotate
See point 4
Pump rotates in the wrong direction
Invert rotation
Not suitable detergent
Change
6 – Pump leaks water
Mechanical seal is worn
Replace
In case of electrical overload the pumps and motors may stops.
In this case re-engage the circuit breakers by pushing the ON button on circuit breaker itself.
In case of continuous anomaly have the cause verified by a qualified electrical technician