ASSEMBLING AND PREPARING THE MACHINE
REVISIONE: X51-1213 EN
18
MAGIDO GROUP S.r.l.
Electrical connection to power supply
Check the supplied voltage of the user correspond to that on the data plaque on the machine otherwise consult
the manufacturer.
It will a user duty to install protection against short circuit and overload in according to local regulations to
protect the machine supply using circuit breakers and differential switches.
To connect machine to electrical power source proceed as follow
Open the door of the electrical box using the supplied key;
Connect the electrical wire from the main directly to the free terminal blocks of the main switch Q.
Check the supplied voltage of the user correspond to that on the data plaque on the machine otherwise consult
the manufacturer.
It will a user duty to install protection against short circuit and overload in according to local regulations to
protect the machine supply using circuit breakers and differential switches.
Connection of the machine to external power sources must be performed by electricians technically
qualified.
By changing the 3 phases of the machine, the rotation of the pump can be changed. The pump
direction must be clockwise (in the direction of the arrows as indicated in the pictures below). If the
rotation is not correct it is necessary to invert the phase wires to the main power supply.
Connection to the mains supply must be performed by a qualified technician in according
to local regulations.
A
lways connect the machine to the ground.
MORSETTIERA PE - L1,L2,L3