32 MAGICFX FLAMEBLAZER
®
—
User and Installation Manual
3.8
USE THE EMERGENCY STOP
1.
When an emergency occurs or is about to occur with the FLAMEBLAZER, you
press the emergency stop button on the ARM CONTROLLER or on an external
E-STOP (if present). As a result the pressurized air can’t leave the tank and any
related hazard/or property damage is stopped and prevented.
2.
Set the safety key on the ARM CONTROLLER to the OFF position.
3.
Resolve the emergency situation and inspect the FLAMEBLAZER.
4.
Release the emergency stop and perform a reset. For instructions, refer to the
ARM CONTROLLER User and Installation Manual (PART01882).
5.
If DMX is used, set the enable and effect channel back to 0.
4
TROUBLESHOOTING
Code
Meaning
Solution
018
Pressure keeps
dropping.
•
Make sure the fuel can is not empty.
•
If the problem is not solved contact MAGIC FX.
020
Pressure Sensor
Failure.
•
Contact MAGIC FX.
121
Orientation of
device out of
safe bounds.
•
Keep the device within previously described safe
bounds.
Always contact MAGIC FX if any malfunctions or errors occur that cannot be solved
with the instructions as described in this manual.
5
MAINTENANCE
To achieve the maximum service life of the FLAMEBLAZER you must regularly clean
the FLAMEBLAZER and test if it is functioning correctly.
Before conducting any maintenance ensure the machine is switched off and
disconnected from a power source and the machine is not hot from recently being
used. Always use personal protective equipment such as safety glasses and gloves
when handling fuels.
Maintenance task Activity
General clean.
Remove any foreign objects from burn chamber before every
use being careful not to move or damage the spark ignition
probes. Remove any dust or dirt from hose connections with a
non-abrasive damp cloth.