Page 11 of 20
507389-02
Issue 1733
Model
Rise
Range
(°F)
Mid
Rise
(°F)
Indoor
Blower
Speed
Unit
Voltage
(V)
0.1 “ w.c.
0.2 “ w.c.
0.3 “ w.c.
0.4 “ w.c.
SCFM
Temp
Rise
(F°)
SCFM
Temp
Rise
(F°)
SCFM
Temp
Rise
(F°)
SCFM
Temp
Rise
(F°)
HWC9N3311P24A
30 - 60
45
TAP 1
(HEAT) *
208 or 230
645
44
615
47
590
49
565
51
TAP 2
(HEAT)
208 or 230
780
37
755
38
730
39
710
40
TAP 3
(HEAT)
208 or 230
900
32
875
33
855
34
835
34
TAP 4
(COOL)
208 or 230
800
775
755
735
TAP 5
(COOL)
208 or 230
880
860
835
815
HWC9N4411P24A
35 - 65
50
TAP 1
(HEAT)
208 or 230
645
59
615
62
590
65
565
N/A
TAP 2
(HEAT) *
208 or 230
780
49
755
51
730
52
710
54
TAP 3
(HEAT)
208 or 230
900
43
875
44
855
45
835
46
TAP 4
(COOL)
208 or 230
800
775
755
735
TAP 5
(COOL)
208 or 230
880
860
835
815
HWC9N5511P24A
45 - 75
60
TAP 1
(HEAT)
208 or 230
645
73
615
N/A
590
N/A
565
N/A
TAP 2
(HEAT)
208 or 230
780
61
755
63
730
65
710
67
TAP 3
(HEAT) *
208 or 230
900
53
875
54
855
55
835
57
TAP 4
(COOL)
208 or 230
800
775
755
735
TAP 5
(COOL)
208 or 230
880
860
835
815
HWC9N4411P30A
35 - 65
50
TAP 1
(HEAT)
208 or 230
735
52
700
55
670
57
640
60
TAP 2
(HEAT) *
208 or 230
825
46
795
48
770
50
745
51
TAP 3
(HEAT)
208 or 230
895
43
865
44
840
46
810
47
TAP 4
(COOL)
208 or 230
800
765
735
715
TAP 5
(COOL)
208 or 230
880
845
820
795
HWC9N5511P30A
45 - 75
60
TAP 1
(HEAT)
208 or 230
735
64
700
68
670
71
640
74
TAP 2
(HEAT)
208 or 230
825
57
795
59
770
61
745
63
TAP 3
(HEAT) *
208 or 230
895
53
865
55
840
56
810
58
TAP 4
(COOL)
208 or 230
800
765
735
715
TAP 5
(COOL)
208 or 230
880
845
820
795
N/A: Do not operate unit in heating mode using this blower speed at this external static pressure. Outside of temperature rise range.
*: As shipped for heating operation.
Table 2.
Airflows and Heating Temperature Rises as a Function of External Static Pressure