MagCore EDA Скачать руководство пользователя страница 19

18

MagCore® 

EDA

User Interface Overview

A.  Home- 

Back to main page and clear the process.

B.  Review Setting- 

Back to main page but keep the process.

C.  Load File- 

Load previously saved process.

D.  Setting- 

System status, tip ejection, maintain system.

E.  View Manual-

 

View the manual on your mobile.

F.  View Report- 

Observe and save the result from the test.

G.  Recent- 

Recent saved process.

H.  Reset-  

Reset to default status.

I.  E Stop- 

Emergency stop button.

J.  Link- 

all zone connection instruction.

A

H

I

G

B

C

D

E

F

Make sure to read the safety information to stop 

the machine properly in case an accident occurs.

When an emergency occurs during operating, 

press the 

E-Stop

 button or 

open the door

 to stop 

the instrument immediately.

After the emergency stop, you can press Reset 

to set it back to its original stats.

J

Please contact your dealer for inspection and maintenance when an emergency occurs, such as a collision or an error signal.

Содержание EDA

Страница 1: ...meters 5 OperatingEnvironment 5 Applications 5 Unpacking 6 EDAOnly 6 EDAStandSet 8 OpenLids 10 RemoveSafetyBrackets 11 Accessories 12 Azone 12 Bzone 12 Installation 13 SystemOverview 14 InstallMagCore...

Страница 2: ...e not sure of the type of power supply at your lab consultthesellerorlocalpowercompany Forproductsintendedtooperatefrom batteryorothersources refertotheoperatinginstructions 11 Grounding or Polarizati...

Страница 3: ...Foradetaileddescriptionofinstrumentsetup andhandling refertotheMagCore instrumentOperator sManual StoretheReagentCartridgeat 15to 25 Cbeforeuse Thekitmaynotworkifyouusethereagentsat temperaturesoutsi...

Страница 4: ...sbufferarecompletelyinactivatedandnon infectious Itisrecommendedthatalldisposableplasticsareautoclavedordiscardedunderlocalregulations aftersampleprocessingiscompleted Donoteat drinkorsmokeinthelabora...

Страница 5: ...tfor n tests Warning electricity Instructionmanualmustbereadbeforeoperating Consultinstructionsforuse Alternatecurrentinput Use byDate Nouseperiod Temperaturestorageconditions15 C 30 C Cataloguenumber...

Страница 6: ...ProcessingTime 30 120minutes dependsonsampletype SampleVolume 200 400 1200 4000 l applicationdependent ElutionVolume 40 60 100 150 200 l applicationdependent Yield 200ulwholeblood average6uggDNA 400u...

Страница 7: ...6 MagCore EDA Unpacking EDAOnly Cutoffallplastic packingbelts A Removethe cornerprotectors B Disassembleeach packingsides C...

Страница 8: ...7 www rbcbioscience com Removethescrews alongthemetalbar onbothsidesofthe instrument D Removethefixing plateandmetalbars E Usethepallettruckor forklifttocarryEDAto theareayou veprepared F...

Страница 9: ...8 MagCore EDA EDAStand Set Cutoffallplastic packingbelts A Removeallof the cornerprotectors B Disassembleeach packingsides C...

Страница 10: ...9 www rbcbioscience com Takeouttherampsinside thestandingcabinet E Theloadingrampscan helpyouunloadtheEDA setatease F Removethescrews onthemetalfixing plateateachcorners D...

Страница 11: ...10 MagCore EDA OpenLids Turnthelockpointto90 byusing ahexscrewdriver andthenyoucan takeoffthelids Besuretotakeoffthesidelids whenremovingfixingplate...

Страница 12: ...ioscience com RemoveSafety Brackets A B E F G C D H E F G A B C D H A Piston out Azone B Piston side Azone C Piston out Bzone D Piston side Bzone E Drawer Azone F Spectrophotometer G Cooler EL ER H Dr...

Страница 13: ...ipetteTipX20 10 MagCoreEDACuvette 10pcs X1 11 TrashCanwithTubeRackX1 12 BarcodeScannerX1 13 TypeAconnectorX1 1 2 3 4 5 7 6 8 9 10 11 12 13 YoucanpurchaseCat No P46040013 MSC100MagCoreCuvetteSet X100 f...

Страница 14: ...the voltage of the outlet is between 220V and 240V Keep your hands dry Also make sure that the machine is turned off when you insert theplug Pluginthepowercordandturnonthemainpower Installation 1220mm...

Страница 15: ...4 MagCore EDA System Overview PLCModule Mainboard Coolingfans TopServiceLid FrontDoor LogoIndicator OperationArea A Zone OperationArea Bzone Hepa Cooler PowerOutlet EthernetPort USBPort MainPowerSwitc...

Страница 16: ...4oftheT Rack Insertthefrontofthecartridgeintothespace underthefixingrackofthecartridgeRack MakesuretoinserttheCartridge RackfirstbeforeT Rack W5 5mlTube W4 200 lSPTip W3 TipHolderset W2 DNase TipHolde...

Страница 17: ...direction Pre coolingPremixReagentRackina 20 Cenvironment freezer Whentakenout itcanlastupto30minutes Thesurfacemightcondensesomewaterwhen takenoutfromthefreezer BesuretowipeoutextradropletsonthePremi...

Страница 18: ...17 www rbcbioscience com BeforeStarting RemovethecapofUSBport LinkMagcoreEDAtocomputerwithprovidedTypeAconnector...

Страница 19: ...entsavedprocess H Reset Resettodefaultstatus I EStop Emergencystopbutton J Link allzoneconnectioninstruction A H I G B C D E F Make sure to read the safety information to stop themachineproperlyincase...

Страница 20: ...entkityouwantto use andselectthekitnumberonthesoftware page KitBarcodecanbefoundonthekitpackage Aftercompletingthescan clickonNexttocontinue theprocess 8 Thenumbercanbefoundin thestickeronthecartridge...

Страница 21: ...toperformtheextraction Makesurethedooranddrawerareclosed 11 Thebuilt inscannerautomaticallyscansthe barcodeontheprimarytubes PulloutthedrawerinAzoneandslowlypushitin ClicktheAutoPrimaryScanoption TheE...

Страница 22: ...lution thenplacethemontherack YouonlyhavetoselectPreMixAcheckbox PositiveandNegativecontrolwillshowinslot23and24 Standardwillshowintheslotbetween17 22 ThesetupNTCwillshowinslot12 Premixwater didnotset...

Страница 23: ...platevolumeforyou YoucancheckthecheckboxtoactivateTemplate Mixataspirate MixatDispense 7 AtDeckLayout 1 4 draganddroptherackinto thedeck Clickonawellatthelasttippositionyou ve inserted Therackwillfill...

Страница 24: ...ack Drag ReactionintoPCRrack 9 MakesurerefertothenumberdisplaysinEstimated Vol ul addtheliquidinthetubetothesameor highervolume andkeyintheactualvolumeinto ManualInput ul Makesurethedooranddrawerarecl...

Страница 25: ...ectedtothemachine 1 2 ClicktheSerialDilutionbuttontomakethesetup 3 SetuptheconditionsforSamples Tubetypeand DilutionBlanks Selectsamplesinthelistandclickthedilute multiple The markmeansthatsomeunitsha...

Страница 26: ...5 Thetiprackcanbedraggedanddroppedto positions1 4inthedecklayout Clickthelocationofthetipboxcontainingthetips bluecirclesindicatethatthereareavailabletips YoucanclickClear ifyouneedtoresettherackposit...

Страница 27: ...neormoretipson theRack Makesurethedooranddrawerareclosed Confirmandcheckallyoursetup pressStartto execute 7 MakesurerefertothenumberdisplaysinEstimated Vol ul addtheliquidinthetubetothesameor highervo...

Страница 28: ...to perform andselectthekitnumberonthesoftware page 3 Confirmyoursettings clickManualScan Barcodetocontinuetheprocess 4 ScanSampleorElution KitBarcodecanbefoundonthekitpackage Aftercompletingthescan cl...

Страница 29: ...nthe barcode PullouttheAzonedrawer andthenslowlypushin 8 Confirmandcheckallyoursetup moveontoB ZonetosetupPCRassay ChooseoneofthethreemodefromManual PCR Kit andAutomatic 10 Formoredetailedinformationa...

Страница 30: ...e morethanoneassay pleasegobacktoPremix ManualSetuppagetosetup 13 11 12 Youcanclickclearifyouneedtoresettherackposition Thetiprackcanbedraggedanddroppedto positions1 4inthedecklayout Clickthelocationo...

Страница 31: ...heemptydeck IntheExtractandAssaySetup thesamples Template areinEL ERslots Drag ReactionintoPCRrack AftertheAandBzonesettingsarecompleted click ExecuteExtraction andtheEDAstartstoexecute thenucleicacid...

Страница 32: ...thecartridge 3 Confirmyoursettings clickManualScan Barcodetocontinuetheprocess 4 ScanSampleorElution 6 UseBarcodeScannertoscanthebarcodeofthe stickeronthetube IftheSampleNumberSettingvalueis 24 waitfo...

Страница 33: ...andkeyinDilute tosameconcentrationvalueyouneed Thebuilt inscannerwillautomaticallyscanthe barcodeontheprimarytubes PulloutthedrawerinAzoneandslowlypushitin 8 ConfirmandcheckallyoursettingsinAzoneand...

Страница 34: ...kthelocationofthetipboxcontainingthetips bluecirclesindicatethatthereareavailabletips Ifyouwantthesamplesolutiontoperformmixing actions youcanchecktheboxintheform Clickthe Assay thenenterthetotalreact...

Страница 35: ...wer the Tip requirement you need to go back to Deck Layout 1 4 to add oneormoretipsontheRack Makesurethedooranddrawerareclosed Whenallyoursetupwerecheckup pressContinue tostartfinalassayprocess 15 14...

Страница 36: ...hedoorisclosed youcandecideto continueoraborttheprogress Duringprogramprocessing youcanpauseor abortthecurrentexecution PressPauseandthemachinesuspendsoperation immediately ClickAbort tocancelallprogr...

Страница 37: ...eorBZone Youcancheckthesystemstatusonthesettingpage System EjectTip Onthesettingpage youcancheckthesystem ejectthetip andmaintaintheEDAdevice Usersneedtoperformthesechecksregularlyto ensurethesystemis...

Страница 38: ...bnormalsituationoccurs youcanpauseandabortthe movementprocess ThefollowingstepsforreplacingtheO ring 1 RemovethedamagedO Ring 2 ReplacetheO ringwithanewone 3 ApplygreasetotheO ringandperformthepistont...

Страница 39: ...dandwhetherthetipcanbe takenoutfromtheT Racksmoothly SelectthewelloftheT rackwherethetip wolud liketobetested 2 Followthesteps thenclickNexttocontinuethe test Hereisanexampleofthepistontestbyclicking...

Страница 40: ...ndabortthemovementprocessifthere san abnormalsituation 1 SelectHeater CoolerTesttostartthetesting procedure 1 TherearetwotemperaturesforAzone sheating andoneforcoolingsystem Beforetestingtheheater ple...

Страница 41: ...ordcanbe providedtoengineerssothattheycandetermine thecauseofmachinefailure Themachinecanrecordthealarminghistory happeningintheAzoneorBzoneseparately Thealarmrecordcanauto generateandsaveintheEDAsyst...

Страница 42: ...41 www rbcbioscience com MagCore EDA...

Страница 43: ...42 MagCore EDA...

Страница 44: ...15F No 15 QiaoheRd ZhongheDist NewTaipeiCity235029 Taiwan TEL 886289121200FAX 86289121300...

Отзывы: