![Maestro MICROTRACKER MT-01 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/maestro/microtracker-mt-01/microtracker-mt-01_product-specifications_3387893045.webp)
Default setting: <AGPS> = 0
Example:
Activated A-GPS
Command: SG554,1
Response: @352238020015913,554,1!
SG555: Change the voltage detection level for the virtual ignition
Command: SG555,<MODE>,<BVC>,<BVT>
Response (SMS): @<ID>,555,<MODE>,<BVC>,<BVT>!
–
Where <MODE> is
•
0 = Read the values
•
1 = Set new values
–
Where <BVC> times 16 is the voltage level for Car battery in mV
–
Where <BVT> times 16 is the voltage level for Truck battery in mV
Default setting: <BVC> = 862*16 = 13792
≈
13.8V, <BVT> = 1593*16 = 25488
≈
25.5V
Example:
Change the voltage detection level for the virtual ignition to 13.8V and 25.5V
Command: SG555,1,862,1593
Response: @352238020015913,555,1,862,1593!
SG556: Control digital output 2
Command: SG556,<state>
Response (SMS): @UID,556,<DO2>!
–
Where <DO2> is the output 2 state
•
1 is output High
•
0 is output Low
Default setting: <DO2> = 0
Example:
Switch the digital output 2 to High.
Send: SG556,1
Response: @0123456789012,556,1!
SG557: Read the Analog input
Command: SG557
Response (SMS): @UID,557,<AI value>!
Confidential, the whole document is the sole property of Maestro Wireless Solutions ltd.
3603-9, 36/F., 118 Connaught Road West, Sheung Wan, Hong Kong
45