9.1 Environmental Conditions
Operating temperature
-40 … +85
°
C
Operating humidity
Max. 85% r. H., non-condensing, at 85
°
C
MSL JEDEC (Moisture Sensitivity Level) 3
Storage
6 months in original package.
Table 13: Environmental conditions
9.2 Product Qualification
Prior to product qualification the GPS receiver is preconditioned according to
EIA/JEDEC standard JESD22-A113-B / Level 3.
Basic qualification tests:
•
MSL Classification according to J-STD-020C (MSL3 @ 245°C)
•
MSL Rework Compatibility according to J-STD-020C
•
Temperature Cycling –40°C … +85
°
C
•
Temperature Humidity Bias 70
°
C / 85% RH
•
Low / High Temperature Operating –40°C / +85
°
C
•
High Temperature Operating Life +85
°
C
•
Vibration Variable Frequency
•
Mechanical
Shock
Please contact Maestro for detailed information.
9.3 Production Test
Each module is electrically tested prior to packing and shipping to ensure state of the
art GPS receiver performance and accuracy.