9
EN
Variation A1
– Port 1 or 2
Description:
Power is supplied only once. It is supplied to NEBULA with 12 A max. and routed
through to the LEDs, which are connected only to Port 1 or only to Port 2 via GROUND, DATA,
possibly CLOCK, and V+ with 6 A max. load for the port.
Variation B1
– Port 1 or 2
Description:
Power is supplied to NEBULA and supplied separately to the LEDs (as required). The
LEDs are connected only to Port 1 or only to Port 2 via GROUND, DATA, and possibly CLOCK, but
not via V+!
Variation C1
– Port 1 or 2
Description:
Power is supplied only once. It is supplied to the LEDs (as required). The LEDs are
connected only to Port 1 or only to Port 2 via GROUND, DATA, possibly CLOCK, and V+. The power
supply is connected between LEDs and NEBULA, due to the expected voltage drop over the length.
Alternative:
You may connect the power supply at the end of the tape for LEDs that use > 9 V.