HD24/96 Technical Reference
81
Appendix B – List of Parameters and How They’re Saved
Setup Parameters – What’s Saved and When
The HDR24/96 has many setup and configuration parameters and preferences, some of
which you must set before use, others that you set in the course of working through your
project. Some of these parameters remain as defaults until changed, some stick with the
Project but revert to the original settings when you open a new project, others return to a
factory default state whenever you switch projects or power up. This table lists all the
parameters and control states, indicating under what circumstances they’re saved, and their
default state.
Global Preferences
The current setting of these parameters and preferences become defaults. Each time you
power up the HDR24/96, they come up in the same state as you last set them. They retain
their settings when you switch Projects or Playlists, or open a new Project. Any change you
make in these will be carried over to the next power-up or the next Project.
Active Drive
Mouse Speed
Window Frames Color Scheme
Waveform Color Scheme
Footswitch Function
Remote Footswitch Function
FTP Server IP Address
FTP Server Subnet Mask
FTP Server Gateway Address
PDI-8 I/O card Input Sample Rate Conversion
PDI-8 I/O card Channel Status Bits (Professional/Consumer)
DIO-8 I/O card Input Format (ADAT/TDIF)
DIO-8 I/O card Output Format (ADAT/TDIF/Convert)
Generate MTC
Generate SMPTE
MMC Device ID A, B, and C
Sample Clock Source (Internal/Word/Video)
Time Code Source (SMPTE/MTC)
Backup Source Disk Drive (front panel function only)
Backup Destination Disk Drive (front panel function only)
Record Safe (on/off)
One Button Punch (on/off)
Meter Mode (Peak/Average/Both)
Meter Peak Hold (Floating indicator on/off)
Solo Latch (on/off)
View Envelopes (on/off)