8.6. Date/Time
You can adjust the date and time format and change the date and
time in the
Date/Time
menu.
Press
to confirm and save your changes. If you leave the
menu by pressing
, none of your choices will be adopted.
Date/Time
Time format
12h
24h
Time
15
17
pm
:
Date format
yyyy.mm.dd mm.dd.yyyy dd.mm.yyyy
Date
2009
10
21
·
·
Time
You can set the hours and minutes separately. Press the edit-
buttons to change the hours and minutes. The input-menu
abc
appears so that you can make changes.
Time format
The time format can be set to 12h or 24h. Press the respective
choice-button. Depending on the format, you can now adjust the
am/pm
activity-button as well.
Date
The date is arranged by year, month and day. Press the edit-
buttons to change the date. The input-menu
abc
appears so that
you can make changes.
Date format
You have three different date format options: (
yyyy.mm.dd
,
mm.dd.yyyy
,
dd.mm.yyyy
)
.
Press the respective choice-button and the date will be displayed
accordingly.
Note: Please verify the date and time after starting the instrument
for the first time.
8.7. User mode
The
User mode
menu allows you to adjust the settings for access
rights and user administration. You have three different modes
to choose from, enabling you to define passwords and create a
group for multiple users.
User mode
Password
Edit users
Single user
User/Admin
Multi user
8.7.1. Single user
The choice-button
single user
is set by default. In the single
user mode, every user can use the instrument without restric
-
tions to access rights. If the choice-button
single user
is acti-
vated, both the activity-buttons
Password
and
Edit user
are inactive.
8.7.2. User / Admin
The choice-button
User/Admin
allows you to set up one admin-
istrator for the instrument. If the Admin mode is active, only the
administrator can access and change the instrument settings. All
other users are excluded from the settings. The Admin mode is
protected by a password.
To set-up the administrator, press the choice-button
User/Ad-
min
.
User mode
Password
Edit users
Single user
User/Admin
Multi user
Then press the activity-button
Password
. The input-menu
abc
appears and you can enter a password. Press
to
confirm and save your changes. If you leave the menu by press
-
ing
, none of your choices will be adopted.
As soon as you have chosen the „User / Admin“ Mode and de
-
fined a password, the password is requested whenever you turn
on the instrument. To sign in as an administrator, choose the
activity-button
Admin
after the device has been turned on. You
have 10 seconds to press the button, which is indicated by a
timer. Once you press the activity-button
Admin
the input-menu
abc
appears and you can enter the password. The instrument
starts and you can access and change the settings normally.
If a different user than the administrator wants to use the instru-
ment, entering the password is not necessary. Press
, or
wait for 10 seconds until the timer has run out. The instrument
then starts automatically. You can use the device for normal
measurements, but cannot access the instrument settings.
Login
Admin
10
Содержание URYXXON 500
Страница 1: ...URYXXON 500 Handbuch Manual...
Страница 2: ...URYXXON 500 MN Inhalt Index Deutsch 3 English 29...
Страница 3: ...URYXXON 500 Handbuch...
Страница 29: ...URYXXON 500 Manual...