23. Remove all wooden blocks from beneath the header.
CAUTION
Check to be sure all bystanders have cleared the area.
24. Start the engine.
25. Lower the header fully.
26. Shut down the engine, and remove the key from the ignition.
4.1.4
Connecting Rotary Disc Header Hydraulics Using Quick Couplers
–
M1240
Windrowers
To connect the R216 Rotary Disc Header hydraulic hoses to the M1240 Windrower using quick couplers, follow these steps:
If your windrower is equipped with hard plumb connections, refer to
4.1.5 Connecting Rotary Disc Header Hydraulics Using
for connection instructions.
1028852
A
B
C
Figure 4.38: Hydraulic Hoses
1.
Route hose bundle (A) from the rotary disc header, under
the windrower frame, then insert pin (B) into hole (C) in the
windrower frame.
NOTE:
Adding anti-seize to the hose holder pin will make future
removal easier.
NOTE:
Leave hose support loose at this time.
1028679
A
Figure 4.39: Protective Shipping Plugs on R216 SP
Hydraulic Hoses
2.
Remove protective plugs (A) from the ends of the
hydraulic hoses.