214075
69
Revision A
8
Changing the Conditioner
This section applies only to machines that require a conditioner change prior to delivery to the customer. If the
change is
NOT
required, proceed to
6 Lubricating the Rotary Disc Header, page 47
.
The R113 rotary disc header can be operated either with no conditioner or with a polyurethane or steel roll
conditioner. If the header is not conditioner equipped, a shield must be installed.
Follow these instructions to change conditioners.
These instructions apply to all conditioners. Exceptions are identified where applicable.
8.1
Removing the Conditioner
This procedure is applicable when the header is not attached to the windrower. If necessary, detach the header
from the windrower before proceeding.
1.
Open the driveshields. Refer to
9.1 Opening Driveshields, page 83
2.
Remove the conditioner drive belt. Refer to
8.3.1 Removing Conditioner Drive Belt, page 77
.
Figure 8.1: M1170 Hose Bundle
3.
M1170:
Move hose bundle (A) clear of frame and lay on
header.
Figure 8.2: M155E4 Hoses
4.
M155
E4:
Remove two bolts (A) attaching hose
bracket (B) to header frame. Place hose bundle and
bracket onto header. Do
NOT
disconnect hoses
from motor.