215104
186
Revision A
1008944
A
B
C
D
Figure 6.9: Ground Speed Lever
7.
Use the following GSL functions to position the center-link
hook above the header attachment pin:
•
REEL UP (A) to raise the center-link
•
REEL DOWN (B) to lower the center-link
•
HEADER TILT UP (C) to retract the center-link
•
HEADER TILT DOWN (D) to extend the center-link
IMPORTANT:
Hook release must be down to enable self-locking mechanism. If
the release is open (up), manually push it down after hook
engages header pin.
1029715
A
B
Figure 6.10: Hydraulic Center-Link
8.
Lower center-link (A) onto the header with the REEL DOWN
switch on the GSL until it locks into position (hook
release [B] is down).
9.
Check that center-link (A) is locked onto header by pressing
the REEL UP switch on the GSL.
CAUTION
Check to be sure all bystanders have cleared the area.
1008946
A
Figure 6.11: Ground Speed Lever
10. Press HEADER UP switch (A) to raise the header to
maximum height.
11. If one end of the header does
NOT
fully raise, rephase the
lift cylinders as follows:
a.
Press and hold the HEADER UP switch until both
cylinders stop moving.
b.
Continue to hold the switch for 3
–
4 seconds. Cylinders
are now phased.
NOTE:
It may be necessary to repeat this procedure if there is air in
the system.