![MacDon M155E4 2016 Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/macdon/m155e4-2016/m155e4-2016_manual_3215679087.webp)
4.3.3
Calibrating the Header Float Sensors
NOTE:
• The header
MUST
be attached to the windrower to perform this procedure. The cab display module (CDM)
automatically adjusts its programming for each header.
• The Operator can use the left or right FLOAT buttons on the cab display module (CDM) to perform this procedure.
1.
Turn ignition key to RUN, or start the engine.
2.
Press PROGRAM (A) and SELECT (C) on cab display
module (CDM) to enter Programming Mode.
• WINDROWER
SETUP?
is
displayed
on
the
upper line.
3.
Press SELECT (C) until CALIBRATE SENSORS? is
displayed on the upper line.
• NO/YES is displayed on the lower line.
Figure 4.25: CDM Programming Buttons
4.
Press right (B) arrow to select Yes. Press SELECT (C).
• TO CALIBRATE SELECT is displayed in upper line.
5.
Press left (A) or right (B) arrow until HEADER FLOAT
is displayed on the lower line. Press SELECT (C).
• CALIBRATING
FLOAT
is
displayed
on
the
upper line.
• PRESS FLOAT + TO START is displayed on the
lower line.
CAUTION
Check to be sure all bystanders have cleared the area.
Figure 4.26: Header Float
147764
79
Revision A