6.
Press right (C) arrow to select Yes. Press SELECT (D).
• SENSOR INPUT is displayed on the upper line.
• HDR HEIGHT 1.23 V is displayed on the lower line.
7.
Press left (B) or right (C) arrow to cycle between
individual sensor readers.
8.
Press
SELECT
(D)
to
skip
to
EXIT
READ
SENSORS? selection.
Figure 4.99: Header Sensors
9.
Press right arrow to select YES. Press SELECT.
10. Press PROGRAM to exit Programming Mode or press
SELECT to proceed to next DIAGNOSTIC MODE.
4.7.4
Forcing a Header ID
The header must be attached to the windrower to troubleshoot certain issues. If damage has occurred to the
header wiring or no header is available, you can force the windrower control module (WCM) to read a header ID.
The WCM reverts to reading NO HEADER each time the engine ignition is cycled.
IMPORTANT:
Forcing a Header ID that is different from the attached header can damage the windrower and header. Doing so
can lead to vibration, belt failures, and other over-speeding related problems.
1.
Turn ignition key to RUN, or start the engine.
2.
Press PROGRAM (A) and SELECT (C) on cab display
module (CDM) to enter Programming Mode.
• WINDROWER
SETUP?
is
displayed
on
the
upper line.
Figure 4.100: CDM Programming Buttons
147764
111
Revision A