4.8.10
Testing the Double Windrower Attachment (DWA) Drive Activate
Function Using the Cab Display Module (CDM)
IMPORTANT:
Do not over-speed a drive for a significant length of time. Doing so can lead to vibration, belt failures, or other
over-speeding related problems.
NOTE:
• DWA must be attached to windrower and activated under the WINDROWER SETUP menu.
For more
information, refer to
4.4.10 Activating the Double Windrow Attachment (DWA), page 88
• Engine
MUST
be running to perform this procedure.
1.
Turn ignition key to RUN, or start the engine.
2.
Press PROGRAM (A) and SELECT (C) on cab display
module (CDM) to enter Programming Mode. Press
SELECT (C).
• WINDROWER
SETUP?
is
displayed
on
the
upper line.
Figure 4.141: CDM Programming Buttons
3.
Press SELECT (B) until DIAGNOSTIC MODE? is
displayed in upper line.
• NO/YES is displayed on the lower line.
4.
Press right (A) arrow to select Yes. Press SELECT (B).
Figure 4.142: Diagnostic Functions
147764
128