214735
93
Revision A
1023406
A
B
1
2
A
C
Figure 4.101: Knife Pressure Hose Positions
1 - Hose in Storage Position (Rotary Configuration)
2 - Hose to Knife Pressure Receptacle (Auger/Draper Configuration)
M1170 configured with R1 Hydraulic Drive
Bundle (B6621):
7.
If switching from a rotary header to a draper header,
remove hose (A) from storage location (B) and connect
to knife pressure receptacle (C) on frame.
1020151
A
B
C
D
E
F
Figure 4.102: Draper/Reel Multicoupler
8.
Retrieve draper drive and reel control multicoupler (A)
from hose management arm.
9.
Push knob (B) on hydraulic receptacle and pull
handle (C) fully away from windrower.
10. Open cover (D) and position coupler onto receptacle.
Align pins in coupler with slots in handle (C) and push
handle toward windrower so that coupler is locked onto
receptacle and knob (B) snaps out.
NOTE:
Hose connector (F) only on M1170 configured with R1
Hydraulic Drive Bundle (B6621).
11. Remove cover from electrical connector (E), push
electrical connector onto receptacle, and secure by
turning collar on electrical connector clockwise.