III. Printer Setup
Prior to receiving the printer, use the
Site Preparation Guide
(document 0700069) to
ensure that the facility meets or exceeds the requirements for the printer.
Site Requirements
Variable
Requirement
Notes
Main Printer Power
200-240 VAC, single phase,
50/60 Hz, 16 Amps maximum
The included auxiliary 24V
adapter for backup vacuum
power requires a 100VAC
circuit. This is recommended
but not required.
Temperature
68-85º F (20-30º C)
Printer will not operate below
minimum temperature
Humidity
20-80% Non-condensing
40-60% optimal
Installed dimensions,
printer only (tables
stowed)
57” H x 28” D x 108” W
(145 cm x 70 cm x 274 cm)
Installed dimensions,
with tables at max.
extension
57” H x 171” D x 108” W
(145 cm 433 cm x 274 cm)
Installed weight
(printer only)
581 lbs. (263 kg)
Unpacking and Assembly Notes
Installation of the printer requires no assembly of any components. The printer rolls out
of its shipping container after removing the shipping restraints. Be sure to follow the
Unpacking and Installation instructions carefully to ensure that all shipping materials are
removed.
The carriage is secured to the platen by a shipping restraint. Power on the printer and
follow the on-screen prompts directing you to remove the carriage shipping restraints.
Failure to remove the restraints can result in severe damage to the printer.
5400 Technical Training Manual
MacDermid ColorSpan Confidential
Page 9 of 39
MacDermid, Inc. 11311 K-Tel Drive, Minnetonka, MN 55343
Phone: 952-944-9457 Fax: 952-944-8507