background image

 

                                                           Sensopress_LCD_Rev_00_Eng.doc Eng  

 

 

OPERATION AND USE  

 

With  Sensopress  LCD,  is  possible  the  managing  of  a  differential  threshold  for  the  liquid  control  (4 
differential threshold with the multi-channel version).  
 
After having accomplished accurately the electric installation is possible to proceed with the starting of 
the device.  
 
Sensopress  LCD  has  a  liquid  crystal  display  in  which  is  possible  to  visualize  all  the  informations 
concerning  the  device.  It  has  also  three  buttons  with  which  is  possible  to  interact  and  change  the 
parameters. With these is possible to determine the intervention points in which to start or to turn off a 
control relay (4 in the multi-channel version), of any other  power device (pump, engine), or warning 
device (lights, alarm, etc) which have compatible features with those of the device’s relay (relays in the 
multi-channel version) of the device (look at next table). 
 

Output Relay  

Single Output Version 

Multi-channel versione 

Channel 1 

10A 250Vac / 10A 30Vdc 

10A 250Vac / 10A 30Vdc

 

Channel 2 

Not present 

2A 250Vac / 2A 30Vdc 

Channel 3 

Not present 

2A 250Vac / 2A 30Vdc

 

Channel 4 

Not present 

2A 250Vac / 2A 30Vdc

 

 
In the single output version the relay turns on in function of the set differential threshold levels. The 
relay  turns  on  when  the  liquid  reaches  the  high  threshold  and  it  turns  off  when  the  liquid  while 
decreasing reaches the low threshold.  
 
In the multichannel version we have 4 relays available which can manage 4 different and indipendent 
differential thresholds. The relays turn on when the liquid reaches the threshold level set up for that 
channel and they turn off when the liquid decreases to the set up low threshold level, always related to 
that channel.   
There is the possibility to disable the relays of the channel one does not want to use. The relay of the 
disabled channel does not commute

regardless

 

of the threshold levels. 

  
 
 

4.1 

Front Panel  Sensopress LCD 

 

When it turns on the device’s display shows the name of the manufacturer MAC3, the software version 
V20 and the product name SENSOPRESS 
 

 

Figure 3 

No/- button 

Menu Button 

Display LCD alphanumeric 

 
 

 Yes/+ button 

Содержание Sensopress LCD

Страница 1: ...Sensopress LCD User Guide Made in Italy Cod 620020102 Dis 7208 Rev 00 06 2015 Eng...

Страница 2: ...trical Connection 6 4 OPERATION AND USE 9 4 1 Front Panel Sensopress LCD 9 4 2 Visualization Menu 10 4 2 1 Auto Mode 10 4 3 Setting menu 11 4 3 1 CHANNEL Mode 12 4 3 2 LOW Mode 13 4 3 3 HIGH Mode 13 4...

Страница 3: ...the product warranty null WARNINGS Sensopress LCD must be installed following the description on the Installation paragraph Sensopress LCD is an electric device possible water seepage in contact with...

Страница 4: ...of water column measured in water cm Note all the visualized values are in mBar The correct value in water cm is obtained by augmenting the pressure in mBar of 2 1 973 a 4 C Sensopress LCD can be pro...

Страница 5: ...UL94V0 Dimensions 105x90x73 mm Weight 450 g Protection degree IP20 Approval CE Sensors for Sensopress LCD Code PRS00B1A1M20000 Housing BRASS Principle operation Ceramic Capsule piezoresistive calibra...

Страница 6: ...ed with a terminal to which is possible to connect the Sensopress LCD supply wires and also the connecting sensor s wires and those of the relay s output ATTENTION All the inner parts of the device ar...

Страница 7: ...TURN 18 Supply Sensor 15V 19 20 Relay Output 10A 250Vac 10A 30Vdc 21 Contact Normally Closed NC 22 Contact Common C 23 Contact Normally Open NO 24 Figure 1 Connections for the version with a single ou...

Страница 8: ...tput 4 2A 250Vac 2A 30Vdc 10 Normally Open NO 11 Common C 12 Normally Closed NC 13 14 15 Sensor 16 Sensor Mass 17 Riturn Sensor RETURN 18 Power Supply Sensor 15V 19 20 Relay Output 1 10A 250Vac 10A 30...

Страница 9: ...hannel 1 10A 250Vac 10A 30Vdc 10A 250Vac 10A 30Vdc Channel 2 Not present 2A 250Vac 2A 30Vdc Channel 3 Not present 2A 250Vac 2A 30Vdc Channel 4 Not present 2A 250Vac 2A 30Vdc In the single output versi...

Страница 10: ...vention s threshold referred to the chosen channel and specified on the display In Figure 4 the low threshold for channel 1 is 99 cm The high intervention threshold referred to the chosen channel and...

Страница 11: ...AUTO Indicates The water s level in the tank The chosen channel The low and the high threshold set up for the chosen channel The relay s state of the chosen channel CHANNEL Only with the multi channe...

Страница 12: ...nel by pushing the button Yes the chosen channel is indicated on the low left side of the display as shown in Figure 6 Push the button No to enable disable the indicated channel The indication of the...

Страница 13: ...ssible to memorize the set up value and to pass to the changing state request if no button is pushed the device after a few minutes goes to the AUTO state Figure 7 To set up the low threshold of a cha...

Страница 14: ...ANUAL Mode from any other mode by selecting the sign GO to MANUAL with the Menu button and by pushing Yes On the display it is shown the state name Manual and the relay position Relay OFF Relay ON and...

Страница 15: ...timer that riactivate the timed backlight starts again by pushing any button With the Menu button we go to the request of state changing if no button is pushed the device goes to the AUTO state Figure...

Страница 16: ...lso if entering the modes where this is requested At the end of this time the password to enter the mode where this is necessary is asked again The password is not necessary to enter the AUTO and the...

Страница 17: ...d this there is the visualization of Figure 14 By pushing the No button it is possible to enter the procedure of zero setting By pushing the Yes button it is possible to enter on the procedure of the...

Страница 18: ...the Yes button after entered the CALIB Make sure the sensor is put through the water column which needs to be set up On the display is visualized the screen of Figure 17 Figure 17 With the Yes and No...

Страница 19: ...ply some specific loads the device may show anomalous behaviors The software is able to take measures and restore the correct operation If there are inductive loads particularly irksome with disturban...

Страница 20: ...Sensopress_LCD_Rev_00_Eng doc Eng 20 Via Maestri del Lavoro 25 27 50013 Campi Bisenzio FI ITALY Tel 39 055 88 77 672 39 055 88 77 372 39 055 88 79 276 Fax 39 055 88 77 068...

Отзывы: