                                                           Sensopress_LCD_Rev_00_Eng.doc Eng  

 

14 

 

LEVEL:  301  cm  in  Figure  8).  By  pushing  the 

Yes/+,  No/-

  buttons  it  is  possible  to  increase  or  to 

decrease the wanted maximum threshold; the maximum threshold cannot be lower than the minimum 
one; if this gets reached the device will start again from the point 899 cm; with the 

Menu

 button it is 

possible  to  memorize  the  set-up  value  and  it  is  possible  to  go  to  the  changing  state  request;  if  no 
button is pushed the device goes to the 

AUTO

 state.  

 
 
 
 
 

 

 

Figure 8 

 
 
To  set-up  the  high  threshold  of  a  channel  which  is  not  the  chosen  one  it  is  necessary  to  go  to  the 
CHANNEL mode and choose the wanted channel by following the instructions described in paragraph 
4.3.1 

CHANNEL Mode

 

4.3.4 

MANUAL Mode 

 
The   

MANUAL

  Mode  is  necessary  to  activate  or  disactivate  manually  the  relays  of  the  different 

channels.  
It is possible to enter the MANUAL Mode from any other mode by selecting the sign 

GO to MANUAL

 

with the 

Menu

 button and by pushing 

Yes/+

 
On the display it is shown the state name  (

Manua

l) and the relay position (Relay: OFF, Relay: ON) 

and  the  number  of  the  channel  correspondent  to  the  relay.  (in  the  single  output  version  there  is  no 
channel indication) 
In the 

MANUAL 

state

 

, by pushing button 

Yes/+,

 it is possible to intervene on the relay, so that to pass 

from ON to OFF  
Button 

No/-

 is used to select the channel on which one wants to intervene manually.  

The activating of the relay in the 

MANUAL

 mode is not linked to the channel state. It can be enabled 

or disabled.  
With the  

Menu

 button it passes to the state of chaning request.  

 
NOTE  

!Attention: in the MANUAL state the device does not go back automatically to the 

AUTO 

state!   

 

              If needed to leave the MANUAL state use the Menu button as usual. 
 

Chosen channel 

In the single 

output version 

it is shown  

 HIGH 

High threshold possible to set-up, 

for the chosen channel,  with the 

Yes/+ e No/- buttons  

Low threshold currently set-up for 

the chosen channel  

Содержание Sensopress LCD

Страница 1: ...Sensopress LCD User Guide Made in Italy Cod 620020102 Dis 7208 Rev 00 06 2015 Eng...

Страница 2: ...trical Connection 6 4 OPERATION AND USE 9 4 1 Front Panel Sensopress LCD 9 4 2 Visualization Menu 10 4 2 1 Auto Mode 10 4 3 Setting menu 11 4 3 1 CHANNEL Mode 12 4 3 2 LOW Mode 13 4 3 3 HIGH Mode 13 4...

Страница 3: ...the product warranty null WARNINGS Sensopress LCD must be installed following the description on the Installation paragraph Sensopress LCD is an electric device possible water seepage in contact with...

Страница 4: ...of water column measured in water cm Note all the visualized values are in mBar The correct value in water cm is obtained by augmenting the pressure in mBar of 2 1 973 a 4 C Sensopress LCD can be pro...

Страница 5: ...UL94V0 Dimensions 105x90x73 mm Weight 450 g Protection degree IP20 Approval CE Sensors for Sensopress LCD Code PRS00B1A1M20000 Housing BRASS Principle operation Ceramic Capsule piezoresistive calibra...

Страница 6: ...ed with a terminal to which is possible to connect the Sensopress LCD supply wires and also the connecting sensor s wires and those of the relay s output ATTENTION All the inner parts of the device ar...

Страница 7: ...TURN 18 Supply Sensor 15V 19 20 Relay Output 10A 250Vac 10A 30Vdc 21 Contact Normally Closed NC 22 Contact Common C 23 Contact Normally Open NO 24 Figure 1 Connections for the version with a single ou...

Страница 8: ...tput 4 2A 250Vac 2A 30Vdc 10 Normally Open NO 11 Common C 12 Normally Closed NC 13 14 15 Sensor 16 Sensor Mass 17 Riturn Sensor RETURN 18 Power Supply Sensor 15V 19 20 Relay Output 1 10A 250Vac 10A 30...

Страница 9: ...hannel 1 10A 250Vac 10A 30Vdc 10A 250Vac 10A 30Vdc Channel 2 Not present 2A 250Vac 2A 30Vdc Channel 3 Not present 2A 250Vac 2A 30Vdc Channel 4 Not present 2A 250Vac 2A 30Vdc In the single output versi...

Страница 10: ...vention s threshold referred to the chosen channel and specified on the display In Figure 4 the low threshold for channel 1 is 99 cm The high intervention threshold referred to the chosen channel and...

Страница 11: ...AUTO Indicates The water s level in the tank The chosen channel The low and the high threshold set up for the chosen channel The relay s state of the chosen channel CHANNEL Only with the multi channe...

Страница 12: ...nel by pushing the button Yes the chosen channel is indicated on the low left side of the display as shown in Figure 6 Push the button No to enable disable the indicated channel The indication of the...

Страница 13: ...ssible to memorize the set up value and to pass to the changing state request if no button is pushed the device after a few minutes goes to the AUTO state Figure 7 To set up the low threshold of a cha...

Страница 14: ...ANUAL Mode from any other mode by selecting the sign GO to MANUAL with the Menu button and by pushing Yes On the display it is shown the state name Manual and the relay position Relay OFF Relay ON and...

Страница 15: ...timer that riactivate the timed backlight starts again by pushing any button With the Menu button we go to the request of state changing if no button is pushed the device goes to the AUTO state Figure...

Страница 16: ...lso if entering the modes where this is requested At the end of this time the password to enter the mode where this is necessary is asked again The password is not necessary to enter the AUTO and the...

Страница 17: ...d this there is the visualization of Figure 14 By pushing the No button it is possible to enter the procedure of zero setting By pushing the Yes button it is possible to enter on the procedure of the...

Страница 18: ...the Yes button after entered the CALIB Make sure the sensor is put through the water column which needs to be set up On the display is visualized the screen of Figure 17 Figure 17 With the Yes and No...

Страница 19: ...ply some specific loads the device may show anomalous behaviors The software is able to take measures and restore the correct operation If there are inductive loads particularly irksome with disturban...

Страница 20: ...Sensopress_LCD_Rev_00_Eng doc Eng 20 Via Maestri del Lavoro 25 27 50013 Campi Bisenzio FI ITALY Tel 39 055 88 77 672 39 055 88 77 372 39 055 88 79 276 Fax 39 055 88 77 068...

Отзывы: