Figure 16

 

 
By pushing the 

Yes/+

 button it is possible to make the zero setting and on the display it is shown the 

writing 

SAVING

…….for a few seconds, after which the device turns in the 

AUTO

 Mode.  

By  pushing  the 

Menu

  button  there  is  the  possibility  to  go  out  from  the  calibration  procedure  without 

saving the zero. It turns back to the 

AUTO

 mode.  

5.1.2 

High Level Calibration 

 
It is possible to enter the calibration of high level by pushing the 

Yes/+

 button after entered the 

CALIB

.  

Make sure the sensor is put through the water column which needs to be  set-up.  
On the display is visualized the screen of Figure 17.  
 

 

Figure 17

 

 
With the  

Yes/+

 and 

No/- 

buttons it is possible to set-up the water column value to which the high level 

calibration needs to be done and to which is put through the sensor.  
Push the 

Menu

 button to enter the saving of the high setting level and it is visualized the screen of 

Figure 18.  
 

 

Figure 18

 

By pushing the 

Yes/+ 

button

 

 it is possible to do the saving of the

 

set-up high level and on the displays 

it is given the writing  

SAVING

….. for a few seconds, after this the device turns in the 

AUTO

 mode.  

Содержание Sensopress LCD

Страница 1: ...Sensopress LCD User Guide Made in Italy Cod 620020102 Dis 7208 Rev 00 06 2015 Eng...

Страница 2: ...trical Connection 6 4 OPERATION AND USE 9 4 1 Front Panel Sensopress LCD 9 4 2 Visualization Menu 10 4 2 1 Auto Mode 10 4 3 Setting menu 11 4 3 1 CHANNEL Mode 12 4 3 2 LOW Mode 13 4 3 3 HIGH Mode 13 4...

Страница 3: ...the product warranty null WARNINGS Sensopress LCD must be installed following the description on the Installation paragraph Sensopress LCD is an electric device possible water seepage in contact with...

Страница 4: ...of water column measured in water cm Note all the visualized values are in mBar The correct value in water cm is obtained by augmenting the pressure in mBar of 2 1 973 a 4 C Sensopress LCD can be pro...

Страница 5: ...UL94V0 Dimensions 105x90x73 mm Weight 450 g Protection degree IP20 Approval CE Sensors for Sensopress LCD Code PRS00B1A1M20000 Housing BRASS Principle operation Ceramic Capsule piezoresistive calibra...

Страница 6: ...ed with a terminal to which is possible to connect the Sensopress LCD supply wires and also the connecting sensor s wires and those of the relay s output ATTENTION All the inner parts of the device ar...

Страница 7: ...TURN 18 Supply Sensor 15V 19 20 Relay Output 10A 250Vac 10A 30Vdc 21 Contact Normally Closed NC 22 Contact Common C 23 Contact Normally Open NO 24 Figure 1 Connections for the version with a single ou...

Страница 8: ...tput 4 2A 250Vac 2A 30Vdc 10 Normally Open NO 11 Common C 12 Normally Closed NC 13 14 15 Sensor 16 Sensor Mass 17 Riturn Sensor RETURN 18 Power Supply Sensor 15V 19 20 Relay Output 1 10A 250Vac 10A 30...

Страница 9: ...hannel 1 10A 250Vac 10A 30Vdc 10A 250Vac 10A 30Vdc Channel 2 Not present 2A 250Vac 2A 30Vdc Channel 3 Not present 2A 250Vac 2A 30Vdc Channel 4 Not present 2A 250Vac 2A 30Vdc In the single output versi...

Страница 10: ...vention s threshold referred to the chosen channel and specified on the display In Figure 4 the low threshold for channel 1 is 99 cm The high intervention threshold referred to the chosen channel and...

Страница 11: ...AUTO Indicates The water s level in the tank The chosen channel The low and the high threshold set up for the chosen channel The relay s state of the chosen channel CHANNEL Only with the multi channe...

Страница 12: ...nel by pushing the button Yes the chosen channel is indicated on the low left side of the display as shown in Figure 6 Push the button No to enable disable the indicated channel The indication of the...

Страница 13: ...ssible to memorize the set up value and to pass to the changing state request if no button is pushed the device after a few minutes goes to the AUTO state Figure 7 To set up the low threshold of a cha...

Страница 14: ...ANUAL Mode from any other mode by selecting the sign GO to MANUAL with the Menu button and by pushing Yes On the display it is shown the state name Manual and the relay position Relay OFF Relay ON and...

Страница 15: ...timer that riactivate the timed backlight starts again by pushing any button With the Menu button we go to the request of state changing if no button is pushed the device goes to the AUTO state Figure...

Страница 16: ...lso if entering the modes where this is requested At the end of this time the password to enter the mode where this is necessary is asked again The password is not necessary to enter the AUTO and the...

Страница 17: ...d this there is the visualization of Figure 14 By pushing the No button it is possible to enter the procedure of zero setting By pushing the Yes button it is possible to enter on the procedure of the...

Страница 18: ...the Yes button after entered the CALIB Make sure the sensor is put through the water column which needs to be set up On the display is visualized the screen of Figure 17 Figure 17 With the Yes and No...

Страница 19: ...ply some specific loads the device may show anomalous behaviors The software is able to take measures and restore the correct operation If there are inductive loads particularly irksome with disturban...

Страница 20: ...Sensopress_LCD_Rev_00_Eng doc Eng 20 Via Maestri del Lavoro 25 27 50013 Campi Bisenzio FI ITALY Tel 39 055 88 77 672 39 055 88 77 372 39 055 88 79 276 Fax 39 055 88 77 068...

Отзывы: