Mac Medical WT0004 Скачать руководство пользователя страница 5

Instruction Manual

MAN-070

5

www.macmedical.com

UNPACKING INSTRUCTIONS

Inspection

1.  Receiving area must meet all State and Local 

regulations prior to unpacking.

2.  Customer must inspect skid and Table both before 

and after unpacking to determine if any items 

were damaged during shipping.

3.  All damaged items must be listed on the Bill of 

Lading.

4.  Customer is responsible for the proper disposal of 

all packing materials. The disposal of these items 

must meet all State and Local regulations.

Unpacking the Work Table

Work Tables are shipped on well-constructed wooden 

skids. Two steel bands secure the Table to the skid.  

The stainless steel surfaces of the part are protected 

by heavy carbboard end-caps, and by layers of 

plastic wrapping.

Care must be taken while unpacking the table to 

avoid damage. Do not drop tools on the table or 

scratch the surfaces with sharp edges.

IMPORTANT:

 Wear gloves and eyewear during the 

unpacking operation.

Retain all shipping materials until the table is 

completely unpacked and inspected for damage.

5.  Use tin snips to cut the metal bands holding the 

box to the wooden skid (Fig1).

6.  Remove metal staples holding one end of the 

packing carton together. 

7.  Slide out table from side of packing carton with 

two attached cardboard end caps (Fig 2).

8.  Remove 2 cardboard end caps.

9.  Remove the plastic protective wrapping.

Caution!

 Do not use a box cutter or 

any other cutting utensil to remove 

the plastic wrapping around the table. 

These items can scratch the protective 

coating on the stainless steel allowing 

the surface to rust.

10.  The Work Table is now ready for use.

11.  Discard shipping and packing materials in 

compliance with state and local regulations.

12.  When not in use, tables must not be double 

stacked while in storage. While still in their 

shipping cartons, tables must not be double 
stacked when not in use.

Fig. 1: Boxed Table

Fig. 2: Wrapped table with end caps.

Содержание WT0004

Страница 1: ...N MANUAL Read and understand all of the instructions and safety information in this manual before operating this product MAN 070 REV A 03 2018 2017 MAC Medical Inc WORK TABLES Manual and Electric Heig...

Страница 2: ...ns 3 GENERAL SPECIFICATIONS 4 Table Installation 4 UNPACKING INSTRUCTIONS 5 MINIMUM MAXIMUM ADJUSTABLE HEIGHTS FOR A WORK TABLE 6 HEIGHT ADJUSTMENT MANUAL HYDRAULIC PUMP WITH HANDCRANK 7 HEIGHT ADJUST...

Страница 3: ...cally friendly adjustable heights adjustable manually or electronically Manual adjustable height range 36 55 Electronic adjustable height range 36 43 H or U brace instead of Under Shelf Full base unit...

Страница 4: ...ation Work Tables with the Electronic Height Adjustment Option require a power source to operate the hydraulics system 1 Place the table so that its left side where its power unit is located is near a...

Страница 5: ...surfaces with sharp edges IMPORTANT Wear gloves and eyewear during the unpacking operation Retain all shipping materials until the table is completely unpacked and inspected for damage 5 Use tin snips...

Страница 6: ...abletop The Maxumim height of a Manual Height Adjust WorkTable is 55 from floor to tabletop Minimum Maximum Adjustable Height Electronic Height Adjustment The Minimum height of an Electronic Adjust Wo...

Страница 7: ...Hydraulic Pump with Handcrank Fig 5 6 the Handcrank can be folded to disappear under the table 1 Crank the table to the desired height 2 Pull the Crank outwards then rotate downward to fold the handle...

Страница 8: ...s Electrical Specifications 4 Memory Positions Primary Voltage 120V 10A Digital Display of the height Engine Voltage 24 VDC Overload Protection Nominal Rating Approximately 340 VA Thermal Protection S...

Страница 9: ...minus e Moving up or down is not possible f Press the S green button to confirm g After the confirmation the display will flash US 036 EU 091 h Use the Up arrow button to move to the upper us 43 EU 10...

Страница 10: ...ss the down arrow The table will now move down Checking with a tape measure lower the table down to US 36 EU 91cm c Then hold 2 until it reads 000 Then press S to set It will then display 036 d Hold t...

Страница 11: ...Pad must be replaced due to damage first remove the existing Memory Control Pad 1 Unplug the table from its power souce 2 Remove four 1 4 screws attaching the Controller to the table mounting plate Fi...

Страница 12: ...the Memory Control Pad to the table mounting plate Fig 11 3 Plug the control pad cable into the round receptacle of the table Power Supply Unit 12 13 4 Plug the table cord back into its power source...

Страница 13: ...le will now move down Verify height of table is US 36 EU 91cm with a tape measure 5 Press and hold 2 button until 000 is displayed Press GREEN SET Button Display will now read 036 6 Press and hold UP...

Страница 14: ...pads Soft bristle brush Mild detergents Sodium Bicarbonate baking soda Distilled water pH rating 7 alone or with a mild detergent White vinegar in a spray bottle Isopropyl Alcohol Hospital grade non b...

Страница 15: ...1 H0135 5 LSS 5 Swivel Caster w Brake 2 All 2 H0090 03 Hydraulic Pump with crank 1 All 1 2 2 The Work Table replacement parts listed on this page have been identified by MAC Medical as serviceable by...

Страница 16: ...actory It is the customer s responsibility to inspect the product for packaging damage before signing the BOL This warranty does not apply to products which have been subject to abuse misuse accident...

Отзывы: