How to setup the Synergic and Manual functions:
1. Turn unit on. Wait for it to go through the power up cycle.
2. Select the SYN MIG icon with the Process Selector button.
the syn. LED is lighting.
3. Select the wire diameter of the wire being used.
so that the wire will not jam or birds nest while feeding.
4. Select the filler wire type. Steel=Fe , AlSi,AlMg = Aluminum, CrNi = Stainless Steel.
Cu=Copper
5. Use the "inductance" control to select the desired arc qualities, and adjust the arc qualities,
whether a stiff, pen-etrating arc with a narrow bead profile and slightly more spatter, or a wider, more
fluid puddle that easily wets in with low amounts of spatter. Overhead welding usually requires a more
stiff penetrating arc. Flat welding will accept a wider, more fluid puddle.
6.2 Stick welding
★
put the switch "7" MMA/CO
2
/PMIG/DPMIG SWITCH into "Stick"
★
Selecting empiric formula: I=40*d ,d is dia. of the electrode.
Notice positive and negative connection during welding.
A negative connection B positive connection
11
ELECTRODE
HOLDER
WORKPIECE
ELECTRODE
HOLDER
WORKPIECE
front panel.
front panel.