36
N
L 1
G
G
L1
N
L1
N
G
L1
N
G
dryer dimensions
MODELS:
LP Gas
Natural Gas
0.055 (1.40) +/-0.001 (0.02) Diameter
0.089 (2.26) +/-0.001 (0.02) Diameter
36.65 in (931 mm)
26.89 in (683 mm)
43 in
(1092 mm)
26.92 in
(684 mm)
electric dryer connection
a.
b.
c.
For this models, an electrical outlet is included that
may contain one of the plugs shown below.
The electrical connection must be performed with the
appropriate electric contat according to the type of
plug of your electrical outlet.
"If the outlet installation does not meet the
specifications, have aproper outlet installed by a
licensed electrician."
Before proceeding, read the following instructions:
Your electrical installation must have one line with
voltage (line 1), a neutal (w/o voltage) and a
ground. You must have a neutral line independent
from the grounding one. The voltage in Line 1
must be 220 V.
Valve
type
Diameter perforation in
inches
Depth
(includes handle)
electric dryer connection
Connect the grounding wire to the central
screw of the terminal block.
Connect live wire to the upper outer
screw of the terminal block (marked L1)
Connect the neutral wire to the lower
outer screw of the terminal block
(marked N)
Ensure that ground strap is connected to
neutral (center) terminal block and to green
ground screw on cabinet rear.
Tighten all terminal block screws (3) of
terminal block.
Turn off the circuit breaker (30 amps) or remove the
dryer's circuit fuse at the electical box. Verify that
the dryer cord is unplugged from the socket.
Remove the power cord cover located at the
lower back. Install 3/4 in. UL recognized strain
relief to power cord entry hole. Bring power
cord through strain relief. Connect power cord
as follows:
50