120 Volt Installation Units
Electrical Requirements
Letter Requirement
E
- 120 volt/40 amp.
- 60 Hz
- Single phase
- 3-wire service (line 1, neutral and
ground)
F
- 120 volt/30 amp.
- 60 Hz
- Single phase
- 3-wire service (line 1, neutral and
ground)
G
- 120 volt/20 amp.
- 60 Hz
- Single phase
- 3-wire service (line 1, neutral and
ground)
H
- 120 volt/15 amp.
- 60 Hz
- Single phase
- 3-wire service (line 1, neutral and
ground)
240 Volt Installation Units
Electrical Requirements
Letter
Requirement
A
- 240 volt/60 amp.
- 60 Hz
- Single phase
- 4-wire service (line 1, line 2 neu-
tral and ground)
B
- 240 volt/50 amp.
- 60 Hz
- Single phase
- 4-wire service (line 1, line 2, neu-
tral and ground)
C
- 240 volt/40 amp.
- 60 Hz
- Single phase
- 4-wire service (line 1, line 2, neu-
tral and ground)
D
- 240 volt/30 amp.
- 60 Hz
- Single phase
- 4-wire service (line 1, line 2, neu-
tral and ground)
Number
Meaning
1
The heater will remain running with pump(s) on high speed.
2
The heater can be activated only with the pump on low speed. Only the spa light
can be operating at the same time without disabling the heater. See your autho-
rized dealer to select this option.
INSTRUC TIONS:
Find your spa listed within the charts on pages 16-20 of this manual then refer to
the key below to determine what electrical service your spa requires.