240 Volt Installation
Permanently Connected
Models:
• The California Cooperage® Models 106 and 107
must be connected to a 240-volt electric service.
Models 103, 104 and 105 are convertible to either
120-volt or 240-volt, but come factory wired for
240-volt service.
Electrical Requirements:
• 240 Volts, 60Hz, Single Phase, 50 amp. 4-wire
service (line 1, line 2, neutral, and ground) or,
*30 Amp Option
Note: The heater can be activated only with the
pump on low speed. Only the spa light can be oper-
ating at the same time without disabling the heater.
See your authorized dealer to select this option.
Spas installed for 240 volt operation require a 4-
wire, 50 amp., 240 volt subfeed in non-metallic
pipe to the spa equipment compartment (line 1, line
2, neutral and ground). A green colored terminal
(or wire connector marked “G”, or “GR”,
“Grounding”) is provided in the control box. To
reduce the risk of electrical shock, connect this ter-
minal or connector to the grounding terminal of
your electrical service or supply panel with a con-
tinuous green insulated copper wire equivalent to
the circuit conductor supplying this equipment, but
no smaller than No. 12 AWG. In addition, a second
pressure wire connector is provided on the surface
of the control box for bonding to local ground
points. To reduce the risk of electrical shock, this
connector should be bonded with a No. 6 AWG
copper wire to any metal ladders, water pipes, or
any metal within 5 feet of the spa.
Copper wire is recommended for all
electrical connections.
Note:
Units to be operated at 240 volts must have all
electrical connections made by a qualified licensed
electrician in accordance with the National Electric
Code and state/local codes in effect at the time of
installation.
Refer to the manufacturer’s nameplate located on
the kickplate to determine your spa’s
ampere requirements.
8