30
Hakki Pilke 38 Easy
Original
Version 6
8
Solenoid and pressure regulating valves
The pressure regulating valves are adjusted to the correct settings at the factory. The splitter's guarantee
becomes void if the factory adjustments are changed. If you need to change the adjustments, first
contact the manufacturer or retailer and follow their instructions carefully. Changing the valve settings
incorrectly may damage the machine or render it hazardous to operate. The relief valve adjustments can
be changed as follows: loosen the locking nut and rotate the hex socket screw clockwise or anti-
clockwise (when turning screw clockwise, the pressure increases and vice versa). Finally tighten the
locking screw. The locations of the relief valves are indicated in the following figures.
1.
Motor relief valve of the output conveyor (70 bars).
2.
The main relief valve of the machine (210 bars).
3.
Relief valve of the acceleration valve (150 bars).
4.
Motor relief valve of the input conveyor (40 bars).
5.
Relief valve of the saw motor (190 bars).
6.
Relief valve of the splitting valve (190 bars).
Figure 50.
Figure 51.