background image

 

m2m Germany GmbH | Am Kappengraben 18-20 | 61273 Wehrheim | 06081 5873860 

 
 

Table of Contents

 

MCF-LW12TER Operating Manual

 

Important safety information

 

Read this manual before attempting to install the device! Failure to observe recommendations 
included in this manual may be dangerous or cause a violation of the law. The manufacturer 
will not be held responsible for any loss or damage resulting from not following the 
instructions of this operating manual.

 

Do not dismantle or modify in any way.

 

The device is only intended for indoor use. Do not expose it to moisture.

 

The device is not intended to be used as a reference sensor, and enginko Srl will not be held liable for 
any damage which may result from inaccurate readings.

 

Avoid mechanical stress

 

Do not use any detergent or alcohol to clean the device.

 

Содержание enginko MCF-LW12TER

Страница 1: ...of the law The manufacturer will not be held responsible for any loss or damage resulting from not following the instructions of this operating manual Do not dismantle or modify in any way The device...

Страница 2: ...ductmust be collected separately from other waste Please note that the lithium batteries must be removed from the equipment before it is given as waste and disposed separately To remove the batteries...

Страница 3: ...on FW update and data reading Indoor installation Storagetemperature 20 80 C Operating temperature 10 60 C Dimensions 80x80x25mm Weight 150g 2 2 Installation To ensure correct operation and reliable a...

Страница 4: ...ays validate your settings by reading the NFC data after the sensor has restarted 2 3 Power ON OFF The sensor is shipped completely off to prevent battery consumption during storage It is therefore ne...

Страница 5: ...y to carry out a first power on prior to commissioning There are two ways to power on the sensor With NFC Move the NFC antenna of the mobile the exact position varies depending on the model of the sma...

Страница 6: ...ng Sending Receiving Steady state Data error Connection error 2 5 Battery This sensor contains lithium battery which must be disposed of separately MCF LW12TERis provided with one Li SOCl2 battery pac...

Страница 7: ...20 61273 Wehrheim 06081 5873860 detach the batteries from the electronic board batteries are secured with dual locking tape and disconnect from the connectors Connect the new batteries and put them i...

Страница 8: ...m2m Germany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860 Place the rear panel paying attention to the wires Afterthe batteries replacement internal counters need to be resetted...

Страница 9: ...tion you need aunique reset code that must be requested to enginko please provide the DevEUI of the sensor when you ask for that code At the end of the procedure the battery level displays 100 2 6 Fir...

Страница 10: ...m2m Germany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860...

Страница 11: ...m2m Germany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860 Updatethe sensor with LoRaTool...

Страница 12: ...Period Period is the interval in minutes between one measure and the next one The sensor sends three measures for every transmission each one with its own timestamp so the messages interval is twice t...

Страница 13: ...not installed at the sea level the reading of barometric pressures at other elevations must be compensated Set the right altitude value with LoRa Tool app Value can be from 300 to 3000 meters Altitude...

Страница 14: ...e device 3 OTAAMCF88 Over the air activation fixed keys JoinEUI 904e915000000001 AppKey on request 4 OTAAENGINKO Over the air activation fixed keys JoinEUI 904e915000000001 AppKey on request 5 ABP req...

Страница 15: ...ly default public Band select the right LoRaWAN band settings accodingly to country requirements DST set to change DST default none No time sync set to disable time synchronization request default ena...

Страница 16: ...n per day default multiple join allowed 6 Passwords The device can be protected by passwords to avoid unauthorized persons to read data or modify parameters As default passwords are equal to 0 Allowed...

Страница 17: ...ermany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860 Once the passwords are setted to gain access from LoRa Tool to the sensor open the App and set the right values before reading from the d...

Страница 18: ...configure the device using an XML file instead to manually adjust the parameters for details about the file format please ask to enginko This is very useful especially in case of multiple devices conf...

Страница 19: ...nt to overwrite XLS is prevailing on the XML so if both files are enabled if the DevEUI of the device matches one of the DevEUIs in the XLS file LoRa parameters will be setted from this one one These...

Страница 20: ...iptions uplinks and downlinks format and available commands please refer to this document 10 Ordering code Code Description MCF LW12TER MCF LW12TER AS enginko LoRaWAN indoor environmental sensor AS920...

Страница 21: ...nformity Hereby enginko Srl declares that MCF LW12TER complies with the essential requirements and other relevantprovisions of Directive 2014 53 EU 12 Contacts enginko Srl ViaRoma 3 I 28060 Sozzago NO...

Отзывы: