m2m Germany GmbH | Am Kappengraben 18-20 | 61273 Wehrheim | 06081 5873860
5.2 Other settings
Network settings
:
please keep
“Any”
settings. Change it only if Objenious network is used (default_ any).
Network type
:
LoRa syncword can be setted as
“private”(0x12)
instead
“public”
(0x34), butthe NS must be setted
accordingly(default: public).
Band
:
select the right LoRaWAN ® band settings accodingly to country requirements.
DST
:
set to change DST (default: none).
No time sync
:
set to disable time synchronization request (default: enabled).
Normally sensor asks for a time sync at every power on (uplink starting with 01) or, if enabled, once a week.
If not handled in the right way can cause a unnecessary battery consumption (battery life < 2 years).
Please check chapter 2.1
.
UnConfirmed
:
set for unconfirmed uplinks (default: confirmed uplink).