M2I MIO-LPG00 Скачать руководство пользователя страница 4

Industrial I/O Wireless Device Hardware Manual

 

 

M2I Corporation 

11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea,   
Tel: +82-70-465-3366, Fax: +82-31-465-3355, 

www.m2i.co.kr

 

 

4 / 16 

Chapter 1 Safety Precautions 

 

■ Before using the product

 

To use the product safely and effectively, please read the contents of this manual thoroughly before use. Please 
keep  to  the  safety  precaution,  for  it  is  to  prevent  accidents  and  potential  danger  from  occurring.  Safety 
precaution  is  classified  into  ‘Warning’  and  ‘Caution’  and  their  meanings  are  as  follows

Also  the  indicated 

illustrations on the product and in the manual have the following meanings. 

 

Violating the instruction may result in serious personal injury or death. 

 

Violating the instruction may result in slight personal injury or product damage. 

 

Be cautious, for danger may be present. 

 

Be cautious, for there is a possibility of an electric shock. 

 

■  General Precautions 

Do not press the screen with a hard or sharp object (awl, screwdriver, pen) with too strong a force.   
It may cause malfunction of touch due to damage of the front sheet. 
Do not use or store in an environment with high vibration. 
Do not allow foreign objects such as water, liquids, or metal powders to enter the product. This may cause 
breakage or electric shock. 
Use the radio or mobile phone at least 30cm away from the main unit. 
Two or fewer bright spots may appear on the LCD screen, and certain areas may appear brighter, but this is 
not a defect in LCD characteristics. 
Do not store or operate in direct sunlight. Direct sunlight can change the properties of the LCD. 
Do not touch an adaptor or power code with wet hands. It can cause electric shock. 
Do not use this product in explosive environments with flammable liquid, gas, or dust. 
If the product needs long-term storage without using, avoid direct sunlight and keep dry condition. 
 

■  Design Precautions 

For protecting whole control system from outer power input or malfunction of product, protection circuit 
must be installed outside of product.

 

Physical  protection  devices  as  emergency  switch,  limit  switch,  or  motion  interlock  circuit  and  others  to 
prevent a critical damage of whole system’s safety and human accident from the product’s malfunction.   
When  computers  or  other  outer  devices  control  (operation  mode  change)  the  product,  set  interlock  in 

sequence program to protect from any communication errors. 

Input/output  signals  or  communication  cables must  have  at  least  100mm(3.94inch)  distance  from  power 
cable or high-tension wire. Especially communication cables must be set apart from power cables. 

 

■  Wiring Precautions 

Be  sure  the  wiring  is  done  correctly  by  checking  the  product’s  rated  voltage  and  the  terminal  layout. 
Incorrect wiring could result in fire, damage or malfunctions. 
Tighten the terminal screw with the specified torque. If the screws of terminal are loose, it could result in 
short circuit, fire, malfunctions. FG Terminal must be used a dedicated ground. Not doing so could result in 
malfunctions. 

Содержание MIO-LPG00

Страница 1: ......

Страница 2: ...055 Korea Tel 82 70 465 3366 Fax 82 31 465 3355 www m2i co kr 2 16 M2I Corporation Industrial I O Wireless Controller MIO LPG00 Hardware Manual Thank you for using Industrial I O Wireless Controller o...

Страница 3: ...ure Specifications 7 Chapter 4 Part Names and General Specifications 8 4 1 Product Size 8 4 2 Part Names and General Specifications 8 Chapter 5 Operation and Settings 9 5 1 System Configuration 9 5 2...

Страница 4: ...LCD screen and certain areas may appear brighter but this is not a defect in LCD characteristics Do not store or operate in direct sunlight Direct sunlight can change the properties of the LCD Do not...

Страница 5: ...of limits from 10 to 50 or on the surface of control board which high pressure equipment is installed Do not install to the place where strong shock or vibration continuously have impacted on product...

Страница 6: ...etc and Industrial I O wireless device MIO LPE00 by wired wireless method 2 2 Package Contents The components of the product are as follows Before using the product please check that all of the follow...

Страница 7: ...ansmit Wireless Communication Status 3 3 LoRa Communication Specifications Frequency Range TX 922 1 923 1 MHz RX 923 3 MHz Antenna Model and Type 1T1R Dipole Antenna KE L09DM Security Setting AES 128...

Страница 8: ...in daero 327beon gil Dongan gu Anyang si Gyeonggi do 14055 Korea Tel 82 70 465 3366 Fax 82 31 465 3355 www m2i co kr 8 16 Chapter 4 Part Names and General Specifications 4 1 Product Size Model W mm D...

Страница 9: ...tion Status Display RESET System RESET MODE MODE Operation Button FREQ Frequency Ch 0 6 Switch SF SF Setting 0 7 12 Switch RX LED COMM Receive Status TX LED COMM Transmit Status COMM Serial Communicat...

Страница 10: ...and Communication Settings Frequency and Communication Settings can be set by rotary switch or private program 5 3 1 Frequency Select Switch You can select LoRa Frequency If you set this switch as 0...

Страница 11: ...e SF select switch of device should be set as 0 3 LoRa Data Packet LoRa communication s AES Advanced Encryption Standard setting 4 Serial Comm Gateway only Set the mode and specification of serial com...

Страница 12: ...na 3 2dBm Data Security AES 128 6 2 Serial Communication Specifications 6 2 1 RS 232C Items Contents Protocol Full Duplex Synch Asynchronous Communication Distance About 15m Type of Connection 1 1 Con...

Страница 13: ...Pair Cable 3 Please connect Signal Ground and Outer Device s Signal Ground together It will make better noise endurance 4 Do not use shield wire of communication line as signal ground It may cause com...

Страница 14: ...r Power and ground terminal specifications are as follows When installing the power and grounding terminals use the pin terminals to improve electrical transmission and to prevent the power line weari...

Страница 15: ...e range 10 80 RH 3 Is the Surrounding pollution no corrosive gas 2 Power 1 Is the input power in right range 3 Related Items 1 Check the touch pad there is no damage scratch or pollution 2 Check the s...

Страница 16: ...366 Product Category Industrial I O Wireless Controller Model Name MIO LPG00 Operating Temp 10 Ta 50 Power Specifications 24Vdc 3Wor less KC Certificates Copyright M2I Corporation 2022 12 www m2i co k...

Отзывы: