M2 Antenna Systems RC2800PX-AZ Скачать руководство пользователя страница 7

 
 
 

 

PROGRAM MODE DEFINITIONS AND EXPLANATIONS 

 

PROGRAM MODES

:  Modes P1-P6 are PROGRAM modes that permit entering, changing, or re-

viewing programmed system parameters.  PROGRAM  modes P20 through P29 are reserved for 
10 preset  headings. 
 

TO CYCLE THROUGH THE VARIOUS PROGRAMMABLE MODES, 

depress and hold the  

UPPER 

mode button in for 3-5 seconds.  The display will change automatically to mode P20. P20 

is the first of your 10 PRESET headings. More on these later. Bump the 

LOWER

 mode button 

down through modes P6, P5, P4, P3, P2, P1, AND 

P0 CAL

.  Go back up by bumping the 

UPPER

 

mode button. The display will show current mode setting. The FACTORY DEFAULTS are listed 
below.  Most of the time these will never be changed. To program or change any setting, depress 
the "CW" / UP or "CCW" / DOWN buttons until the desired setting is displayed.  Change anything 
or everything in the program mode except P6 and SAVE just once. NOTE: THIS IS DIFFERENT 
FROM OLDER VERSIONS OF RC-2800’s. ( NOTE: DURING PROGRAMMING, THE NUMBERS 
CHANGE SLOWLY AT FIRST THEN SPEED UP. RELEASING THE BUTTON AND PRESSING 
IT AGAIN RESETS THE PROCESS OF SLOW TO FAST NUMBER CHANGE ) 
 

TO ENTER  “PROGRAM MODE“: Press and hold the upper Mode button until P20 appears. 
 P20 through P29 contain preset headings. We put in our favorites but you can choose  
your 10 favorite directions or presets and change the default settings anytime.  One or all 
can be changed and then saved as described below.  
 

Bump the lower mode button once and 

Mode P6 

appears.  For use with the OR2800 

P6 is used  

only to correct your heading if the antenna system was not clamped perfectly at the time 
of installation or if your mast or antenna slips slightly in a high wind.. 

To change to a new 

heading. touch the CW button. 0.0 should appear. Touch CW again. If the digits count up 
( .1, .2 .3 etc.) continue until you near the corrected heading. Let off and press again. IF  THE 
NUMBER WON’T GO UP, WHEN CW IS PRESSED, then press the CCW button and proceed 
until you approach the corrected heading. Let  up and press again.  If you overshoot, press the 
other button until you get to the corrected heading. SAVE by pressing and holding the LOWER 
MODE BUTTON until MODE 0 appears along with the current speed setting and your new, cor-
rected heading; example ( 0 8  23.5). 
 

PROGRAM MODES,  P5, P4, P3, P2, AND P1. THE DEFAULTS ARE SHOWN. 
TO SAVE ANY OR ALL NEW PROGRAMMED SETTINGS AT THE SAME TIME EXCEPT FOR 
P6: 

Depress the 

lower

 mode button UNTIL MODE 0 APPEARS. P6 must be saved as soon as it 

is set. 

 
P5

 = 

1

 This is the minimum SPEED and RAMP setting.  A ‘1’ gives you full speed and ramp con-

trol.  (NOTE: When trouble shooting a faulty operation, to get good motor voltage and reed switch 
readings, it is helpful to temporarily set the speed to 9. This eliminates motor pulses and give a 
steady DC reading for your DVM.) 
 

P4

 = 

3960

 This is the number of pulses from an OR-2800DC or AC for 360 degrees of rotation.  

This number can also relate to the gear ratio of your rotator.  Two pulses are formed for each mo-
tor rotation so your OR-2800 gear ratio is 1930:1. If you use an OR-2800 to turn your tower, and 
you use a 2:1 step down for more torque, your mode P4 number would have to be changed to 2 x 
3960 or 7290.  ( the internal limit switches in the OR-2800 would have to be de-activated by re-
moving the limit arm inside the rotator).  The RC-2800PX can handle pulse counts or gear ratios 
of up to 40,000!  The more pulse counts, the more accurate the rotation control and read-

Содержание RC2800PX-AZ

Страница 1: ......

Страница 2: ...ONTROLS 5 RUN MODES 6 PROGRAMMING MODES CALIBRATION 7 8 PROGRAMMING PRESETS 9 REAR PANEL AND INSTALLATION HINTS 10 OPERATION BY COMPUTER 11 AZ AND EL OPERATION BY COMPUTER 12 WRITING CONTROL SOFTWARE...

Страница 3: ...he WEB Of course this new controller works with any of our older OR 2800DC ro tators It can also be easily modified to work with MOST of our older AC OR 2800AC units as well By ordering an RC 2800PPX...

Страница 4: ...lay will change to read 0 9 L346 The rotator and the control box are now in sync and CALIBRATED THIS PROCEDURE CAN BE RE PEATED ANYTIME IF YOUR CALIBRATION IS LOST CHANGED OR SUSPECT It can also be do...

Страница 5: ...TONS The speed buttons control the positioner s rate of speed in relative increments 1 is the slowest speed 9 is the fastest 0 IS DISPLAYED WHEN THE ROTATOR IS NOT MOVING The top button increases the...

Страница 6: ...e downloaded directly into your RC 2800PX to reduce the reverse delay to 1 sec for special applications General updating will be available from the web site as well MODE 1 Computer control or Manual p...

Страница 7: ...if your mast or antenna slips slightly in a high wind To change to a new heading touch the CW button 0 0 should appear Touch CW again If the digits count up 1 2 3 etc continue until you near the corr...

Страница 8: ...MENTS of the digit to the left of the C start to ro tate counterclockwise at the same time the rotator is moving Counterclockwise CCW Release the LOWER mode button and the rotator will continue going...

Страница 9: ...RELEASE THE BUTTON AND THEN PUSH EITHER CW OR CCW TO GET TO EXACTLY 30 0 DEGREES NOTE THE NUM BERS CHANGE SLOWLY AT FIRST THEN SPEED UP NOW BUMP THE UPPER MODE BUTTON AGAIN AND P21 00 0 SHOULD APPEAR...

Страница 10: ...AND wiring errors are the major cause of opera tional failure Occasionally this even causes rotator or control box failure For short runs of 100 feet or less the wire sizes listed above are adequate F...

Страница 11: ...r of that program a copy of this page and the following two pages regarding writing software HYPER TERMINAL OPERATION A Commands in upper or lower case are acceptable B All commands are followed by an...

Страница 12: ...mper cable to the 10 pin socket labeled J41 on the circuit board with the RED STRIPE DOWN E Bring up the desired control program SKYMOON NOVA or Hyper Terminal F Turn on both units simultaneously or t...

Страница 13: ...cted controller A or E heading and other status is continually streaming down the HYPER TERMINAL screen while positioner is moving Once A azimuth or E elevation is selected the A or E command is no lo...

Страница 14: ...ions returned to the terminal by the controller are followed by a line feed OA and a cr OD No echoes are returned ERROR CODES There are a number of error conditions returned by the controller to the t...

Страница 15: ...ll M2 at 559 432 8873 and we will help you trouble shoot the system If the above appears OK then the missing pulses maybe caused by a control cable problem or a damaged Again turn off the box and remo...

Страница 16: ...4402 N Selland Av Fresno CA 93722 We NOW INCLUDE a copy of the power supply and conditioning and the motor control schematic if you prefer to do the repair Here are some helpful details The Dual Darl...

Страница 17: ...terminal 5 It also turns on a power mosfet that closes the motor cir cuit It then pulses the motor on a few times and watches for some returning pulses If no pulses come back the micro shuts down the...

Страница 18: ...3 U32 LM7812 23VDC 1 MTR ON DC DRV 7 6 THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO M2 ANTENNA SYSTEMS INC ANY REPRODUCTION DISCLOSURE OR USE OF THIS DOCUMENT IS EXPRESSLY PROHIBITED EXCEPT AS M2...

Страница 19: ...incidental damages arising form the use or inability to use the product Some state or prov inces do not allow the exclusion or limitation of liability for consequential or incidental dam ages so the...

Отзывы: