M2 Antenna Systems RC2800PX-AZ Скачать руководство пользователя страница 10

REAR PANEL

 

TERMINAL STRIP 

This 6 terminal strip at left serves as cable interface to 
the rotator unit.  The cable supplies power to and data 
from the rotator.  Your multi-conductor cable from the 
rotator connects here.  A ground stud is provided at right 
end of terminal for shielded cables.  DISCONNECT AC 
POWER CORD WHEN CONNECTING CABLE LEADS.

 

 
“RS232”  

 

This is a 9 pin female (DB9) connector for linking to 
computer RS232 port. 

 

“VAC SELECT” 

 

A flush mounted voltage selection switch for 115 or 230 VAC.  At the factory, we set this switch to “115”. 

 

“FUSE”

 

Provides electrical protection to components.  Replace with a 3 Amp / 250V type. Units designed for use with 
special or prop-pitch motors may require a different fuse , usually a 5 amp. Match factory installed fuse.  A sec-
ond high current fuse may be present on some units controlling large prop pitch and 1/3 hp and up motors. 

 

“AC IN”

 

The AC cord plugs in here. Connect to a reliable 115 VAC or 230 VAC source. Power is filtered to protect com-
ponents.  

TERMINAL ASSIGNMENTS 

TERMINAL    FUNCTION               RECOM. COLOR    MIN WIRE GAGE 
#1                  MOTOR                               BLACK                    AWG 16 
#2                  MOTOR                               WHITE                     AWG 16 
#3 *                3 WIRE MOTOR ONLY      RED                          AWG 16 
#4                  NOT USED 
#5                  REED SW. DC+                  ORANGE                 AWG 24 
#6                  REED RETURN                  BLUE                       AWG 24 

            STUD            CASE GND                          BARE                       NA 
* THREE WIRE MOTORS INCLUDE: AC AND PROP PITCH MOTORS. 
TERMINAL # 1 BECOME MOTOR COMMON. FOR OR2800DC, USE ONLY TERM. 1 AND 2. 
 
INSTALLATION HINTS:  

Poor quality wiring 

or cable AND 

wiring errors 

are the major cause of opera-

tional failure. Occasionally this even causes rotator or control box failure. 
For short runs of 100 feet or less, the wire sizes listed above are adequate. For runs over 100 feet, multi 
conductor cable like Belden 9405 is fine. Since only four total conductors are required, and only two of 
those conductors carry any current, 3 wires can be put in parallel for each motor lead.  The danger here is 
that you mix up the wire colors from one end to the other. Results can be disastrous so be very careful with 
this paralleling technique. Sometimes so much capacitance exists in between the cable wires in long runs 
that the nice SQUARE WAVE pulses formed by the reed switch and rotating magnets at the motor are dis-
torted and contaminated to the point that the microprocessor cannot count them accurately.  A very positive 
FIX for this condition is to use a shielded wire for the pulse / reed switch line.  RG58 is great for this appli-
cation. It is made for outdoor use and it is reasonably rugged and tough and can withstand abuse and still 
get the job done. If you want the KILLER CABLE for all applications, the WIREMAN makes an 8 conductor 
plus one shielded conductor that will operate your OR2800 AC or DC reliably from over 850 feet from the 
RC-2800PX. It is about the size of RG-213. We highly recommend it for those LOOONG runs! Another way 
to handle a long run is to use two large #8 wires and a run of RG58. Run this way to the base of the tower 
and then convert to Belden 9405 or Wireman cable for up the tower to the rotator. 

10 

Содержание RC2800PX-AZ

Страница 1: ......

Страница 2: ...ONTROLS 5 RUN MODES 6 PROGRAMMING MODES CALIBRATION 7 8 PROGRAMMING PRESETS 9 REAR PANEL AND INSTALLATION HINTS 10 OPERATION BY COMPUTER 11 AZ AND EL OPERATION BY COMPUTER 12 WRITING CONTROL SOFTWARE...

Страница 3: ...he WEB Of course this new controller works with any of our older OR 2800DC ro tators It can also be easily modified to work with MOST of our older AC OR 2800AC units as well By ordering an RC 2800PPX...

Страница 4: ...lay will change to read 0 9 L346 The rotator and the control box are now in sync and CALIBRATED THIS PROCEDURE CAN BE RE PEATED ANYTIME IF YOUR CALIBRATION IS LOST CHANGED OR SUSPECT It can also be do...

Страница 5: ...TONS The speed buttons control the positioner s rate of speed in relative increments 1 is the slowest speed 9 is the fastest 0 IS DISPLAYED WHEN THE ROTATOR IS NOT MOVING The top button increases the...

Страница 6: ...e downloaded directly into your RC 2800PX to reduce the reverse delay to 1 sec for special applications General updating will be available from the web site as well MODE 1 Computer control or Manual p...

Страница 7: ...if your mast or antenna slips slightly in a high wind To change to a new heading touch the CW button 0 0 should appear Touch CW again If the digits count up 1 2 3 etc continue until you near the corr...

Страница 8: ...MENTS of the digit to the left of the C start to ro tate counterclockwise at the same time the rotator is moving Counterclockwise CCW Release the LOWER mode button and the rotator will continue going...

Страница 9: ...RELEASE THE BUTTON AND THEN PUSH EITHER CW OR CCW TO GET TO EXACTLY 30 0 DEGREES NOTE THE NUM BERS CHANGE SLOWLY AT FIRST THEN SPEED UP NOW BUMP THE UPPER MODE BUTTON AGAIN AND P21 00 0 SHOULD APPEAR...

Страница 10: ...AND wiring errors are the major cause of opera tional failure Occasionally this even causes rotator or control box failure For short runs of 100 feet or less the wire sizes listed above are adequate F...

Страница 11: ...r of that program a copy of this page and the following two pages regarding writing software HYPER TERMINAL OPERATION A Commands in upper or lower case are acceptable B All commands are followed by an...

Страница 12: ...mper cable to the 10 pin socket labeled J41 on the circuit board with the RED STRIPE DOWN E Bring up the desired control program SKYMOON NOVA or Hyper Terminal F Turn on both units simultaneously or t...

Страница 13: ...cted controller A or E heading and other status is continually streaming down the HYPER TERMINAL screen while positioner is moving Once A azimuth or E elevation is selected the A or E command is no lo...

Страница 14: ...ions returned to the terminal by the controller are followed by a line feed OA and a cr OD No echoes are returned ERROR CODES There are a number of error conditions returned by the controller to the t...

Страница 15: ...ll M2 at 559 432 8873 and we will help you trouble shoot the system If the above appears OK then the missing pulses maybe caused by a control cable problem or a damaged Again turn off the box and remo...

Страница 16: ...4402 N Selland Av Fresno CA 93722 We NOW INCLUDE a copy of the power supply and conditioning and the motor control schematic if you prefer to do the repair Here are some helpful details The Dual Darl...

Страница 17: ...terminal 5 It also turns on a power mosfet that closes the motor cir cuit It then pulses the motor on a few times and watches for some returning pulses If no pulses come back the micro shuts down the...

Страница 18: ...3 U32 LM7812 23VDC 1 MTR ON DC DRV 7 6 THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO M2 ANTENNA SYSTEMS INC ANY REPRODUCTION DISCLOSURE OR USE OF THIS DOCUMENT IS EXPRESSLY PROHIBITED EXCEPT AS M2...

Страница 19: ...incidental damages arising form the use or inability to use the product Some state or prov inces do not allow the exclusion or limitation of liability for consequential or incidental dam ages so the...

Отзывы: