background image

Premier 4-6-0 Camelback

Steam Locomotive

Compatibility

This engine is available in 2-rail and 
3-rail Versions and will operate on 
any O-31 Gauge track system (3-rail), 
42” radius (2-rail) including M.T.H.'s 
RealTrax® and ScaleTrax™ or 
traditional tubular track. It is also 
compatible with most AC and DC 
transformers. See pages 25&26 for  
lists of  compatible transformers and 
wiring instructions.

OPERATOR’S MANUAL

(3V PS-2)

PLEASE READ THIS MANUAL BEFORE USE AND SAVE

WWW.MTHTRAINS.COM

Passenger Station 
Announcement

Содержание Premier 4-6-0 Camelback Steam Locomotive

Страница 1: ...system 3 rail 42 radius 2 rail including M T H s RealTrax and ScaleTrax or traditional tubular track It is also compatible with most AC and DC transformers See pages 25 26 for lists of compatible tran...

Страница 2: ...This product may be protected by one or more of the following patents 6 019 289 6 280 278 6 281 606 6 291 263 6 457 681 6 491 263 6 604 641 6 619 594 6 624 537 6 655 640 2009 M T H Electric Trains Co...

Страница 3: ...ion does not The pickups are factory installed on 3 rail versions and packaged seperately in the locomotive box for 2 rail versions Each pickup roller installs with a single phillips screw Configuring...

Страница 4: ...the transformer to the track or reverse the locomotive s orientation on the track itself Instead simply slide the polarity switch located on the tender as shown below The DCS Polarity Switch should b...

Страница 5: ...to Coupler To install the Proto Coupler on a 2 rail tender follow the step by step instruction listed below First remove the Kadee Coupler Mounting Plate from the bottom of the tender chassis Next rem...

Страница 6: ...not overfill the unit or the fluid may leak out and coat the interior engine components Premier 4 6 0 Camelback Steam Locomotive 6 DO NOT OVER OIL DO NOT OVER OIL DO NOT OVER OIL Lubrication Points o...

Страница 7: ...on In order to mate the connectors of the drawbar and the tender place the engine and tender on the track Then position the tender over the drawbar and insert the drawbar pin into the hole in the draw...

Страница 8: ...ase the Bell button again The bell will continue to ring from the time you turn it on until you press and release the button again to turn it off Horn Whistle To sound the whistle firmly press the Hor...

Страница 9: ...ote To Play the Quillible Proto Whistle press the soft key SPW on the remote When the SPW is highlighted the Quillible Proto Whistle Function is activated The thumbwheel will not control nor change th...

Страница 10: ...ttons to activate features rather than to blow the horn or ring the bell you should tap the buttons very quickly with a second pause between button presses You may need to practice your timing to make...

Страница 11: ...button to trigger the sounds and Proto Sound 2 0 has disabled operator control over the Horn Whistle and Bell buttons until the full FYS PSA sequence is complete After waiting about 30 seconds for th...

Страница 12: ...FYS PSA in Proto Sound 2 0 FYS PSA can be triggered from Neutral It will operate the same as if triggered while in motion except that at the conclusion of the FYS PSA the engine will depart in the ne...

Страница 13: ...engine will run more slowly at a given throttle voltage when speed control is on than when it is off you should adjust the throttle to a lower power level for operation with speed control off to avoid...

Страница 14: ...efault To override the settings you currently have assigned to the engine and reset it to its factory defaults while in Neutral tap the Horn button quickly once followed by five quick taps of the Bell...

Страница 15: ...al grease until after 50 hours of operation or one year whichever comes first To access the gear box and axles do the following 1 Turn the engine upside down 2 Remove the Phillips screws marked GREASE...

Страница 16: ...d a clean rag Unplug the transformer and wipe the rails of the track turning the rag frequently to ensure that you are using clean cloth on the rails Thereafter keep an eye on the track and clean it w...

Страница 17: ...heel You may find it useful to use two small flathead screwdrivers to stretch the tire over the wheel 4 If you twist the tire while stretching it over the wheel you will need to remove and reinstall t...

Страница 18: ...ng com Fax 410 423 0009 Phone 410 381 2500 Mail 7020 Columbia Gateway Drive Columbia MD 21046 1532 To Replace Headlight 1 Remove the body mount screws as shown on Page 14 and separate the boiler from...

Страница 19: ...harged There are a number of ways you can do this Leave the engine in neutral with track voltage at 10 12 volts for 6 7 hours so the battery can fully recharge if your engine has a smoke unit be sure...

Страница 20: ...fluid may leak out and coat the interior engine components If you choose not to add the fluid or have already added the fluid but choose to run smoke free turn off the smoke unit by turning the smoke...

Страница 21: ...hell 3 With the board free of the mounting screws slide the assembly out of the boiler 4 Once the unit is freed remove the inspection cover shown above Inspect the wick if it is darkly discolored and...

Страница 22: ...I can t get the bell to ring when I press the bell button The bell won t work on a separate bell button When I try to fire the coupler FYS starts The Proto Coupler won t let the engine uncouple on th...

Страница 23: ...ked into the neutral position Follow the procedure in the Lock into a Direction section Engine speed must be below 10 scale mph approx 10 volts or less in conventional mode Proto Sound 2 0 volume is s...

Страница 24: ...be as realistic as possible Proto Sound 2 0 disables the reversing unit whenever FYS PSA is enabled This way the engine remains still at its stop as the operator cycles through the FYS PSAsequences FY...

Страница 25: ...nel RW U A 9 19v 110 Watt Standard Lionel SW U A Unknown 130 Watt Standard Lionel TW U A 8 18v 175 Watt Standard Lionel ZW Lionel Post War Celebration Series ZW A B C or D A B C or D U Common 8 20v 0...

Страница 26: ...upplies Proto Sound 2 0 is designed to work with most standard DC power supplies and AC transformers The following charts lists the recommended DC and AC transformers Note that many of the AC operatio...

Страница 27: ...rains but does not turn off the power One Touch Global Mute UnMute Single button mutes or unmutes all DCS controlled locomotives user defined actions including sound lights and smoke Proto Dispatch Op...

Страница 28: ...refully before returning any merchandise for service Authorized M T H Service Centers are independently owned and operated and are not agents or representatives of M T H Electric Trains M T H assumes...

Отзывы: