background image

R7L-RS4

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-7804-C  Rev.5  P. 2 / 19

COMPONENT IDENTIFICATION

ERR

SVCE

ONLINE

TX/RX

PWR

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

4

5

6

7

1

2

3

10 11 12 13

2

3

4

1

15 16 17 18

7

8

9

6

14

5

Reset SW

Factory Configuration Port

Service SW

Status Indicator LED

Indicator LED

L

ON

W

ORKS

, Power Supply

Terminals

Input Terminals

 

STATUS INDICATOR LED

ID

COLOR

STATE

MEANING

PWR

Green

ON

Internal 5V is normal

OFF

Internal 5V is abnormal.

ONLINE Green

ON

Online

Blink

approx.

0.5 Hz

Offline
Sending/receiving of Net-
work
Variables has stopped.

Blink

approx.

2 Hz

Receiving Wink Message

OFF

Abnormal state

ERR

Red

ON

Writing in the non-volatile 
memory

Blink

Abnormal state

OFF

Normal state

TX/RX

Green

ON

Sending/receiving Network 
Variables

OFF

Communication is lost.

SVCE

Green

ON

No network information

Blink

approx.

0.5 Hz

Offline
Sending/receiving of Net-
work
Variables has stopped.

OFF

Normal state

 

INDICATOR LED

Used to show network variable status assigned to fbLED.
     

ON  

: LED ON

     

OFF  : LED OFF

 

SERVICE SWITCH

Used to identify the node in L

ON

W

ORKS

 network configura-

tion.

 

RESET SWITCH

Used to reset the Neuron Chip.  Press the switch behind the 
front cover to reset.
Control functions are halted while completing resetting and 
restarting.  Confirm no danger before conducting resetting.

 

POWER SUPPLY, L

ON

W

ORKS

 TERMINAL ASSIGNMENT

4

NET1

5

NET2

6

U (+)

1

NET1

2

NET2

3

FG

7

V (–)

NO.

ID

FUNCTION, NOTES

1

NET1

L

ON

W

ORKS

 communication 1

2

NET2

L

ON

W

ORKS

 communication 2

3

FG

FG

4

NET1

L

ON

W

ORKS

 communication 1

5

NET2

L

ON

W

ORKS

 communication 2

6

U (+)

Power input

7

V (–)

Power input

Note:   L

ON

W

ORKS

 wiring must be paired between NET1 termi-

nals and/or NET2 terminals.

 

INPUT TERMINAL ASSIGNMENT

10

INA0

11

INb0

12

INA1

1

NC

2

INB0

3

NC

13

INb1

4

INB1

14

NC

5

NC

15

INA2

6

NC

16

INb2

7

INB2

17

INA3

8

NC

9

INB3

18

INb3

NO.

ID

FUNCTION

NO.

ID

FUNCTION

1

NC

No connection

10 INA0 RTD 0-A

2

INB0 RTD 0-B

11 INb0 RTD 0-b

3

NC

No connection

12 INA1 RTD 1-A

4

INB1 RTD 1-B

13 INb1 RTD 1-b

5

NC

No connection

14

NC

No connection

6

NC

No connection

15 INA2 RTD 2-A

7

INB2 RTD 2-B

16 INb2 RTD 2-b

8

NC

No connection

17 INA3 RTD 3-A

9

INB3 RTD 3-B

18 INb3 RTD 3-b

Содержание R7L-RS4

Страница 1: ...POINTS OF CAUTION POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 24V AC rating 24V 10 50 60 Hz approx 85m...

Страница 2: ...ED Used to show network variable status assigned to fbLED ON LED ON OFF LED OFF SERVICE SWITCH Used to identify the node in LONWORKS network configura tion RESET SWITCH Used to reset the Neuron Chip P...

Страница 3: ...mm wide 54 2 13 17 66 4 5 6 7 1 2 3 10 11 12 13 2 3 4 1 15 16 17 18 7 8 9 6 14 5 3 12 5 5 22 50 1 97 18 5 73 115 4 53 7 M3 SCREW TERMINALS for LONWORKS POWER 18 M3 SCREW TERMINALS for INPUT 6 24 6 24...

Страница 4: ...NNECTION HOST PC LONWORKS R7L LONWORKS R7L LONWORKS Terminator WIRING INSTRUCTIONS SCREW TERMINAL Torque 0 5 N m SOLDERLESS TERMINAL Refer to the drawing below for recommended ring tongue terminal siz...

Страница 5: ...g Maximum sending time per fb Minimum sending time per fb Set Tag No name Indicate Model No and Version Indicate Serial No NodeObject Network Variables Configuration Properties Network Variables NETWO...

Страница 6: ...0 0 Maximum time interval to send network variables per fb Power supply must be reset when this configuration prop erty is changed Network variables are sent out in the specified intervals even when...

Страница 7: ...NTOut Set the maximum count Set the value when fbCNT is reset fbCNT SCPTdirection nviCNTIn SCPTinvrtOut nviCNTCtrl SCPTpwrUpState nvoCNTOut SCPTnvType SCPTmaxRnge SCPTsetpoint Network Variables Config...

Страница 8: ...Count always reset to 0 Bit 5 8 through 15 Invalid Minimum input pulse width 500 ms for nviCNTIn 50 ms for the input terminals DO NOT connect a network variable to nviCNTIn when one of the input term...

Страница 9: ...adjustment Gain adjustment 0 and 100 setpoints Zero adjustment Span adjustment fbRS SCPTsceneNmbr nvoRSVal SCPTnvType SCPTminDeltaTemp SCPToffset SCPTdefScale SCPTsetpoint nvoRSPVal SCPToffset SCPTgai...

Страница 10: ...fset 1 SCPToffset 0 SCPTdefScale nvoRSVal SNVT_lev_percent 80 000 120 000 0 0 Gain applied to SCPToffset 0 SCPTsetpoint 0 nvoRSVal Same as nvoRSVal nvoRSVal lower range temperature SCPTsetpoint 0 SCPT...

Страница 11: ...riable type 0 and 100 setpoints Network variable type 0 and 100 setpoints nviCVIn SCPTnumDigits SCPTnvType SCPTsetpoint nvoCVOut SCPTnvType SCPTsetpoint Network Variables Configuration Properties Netw...

Страница 12: ...hat of the source when using 60 63 SCPTnvType nviCVIn SNVT_nv_type SNVT_temp Indicates nviCVIn type For use with LonMaker and other tools SCPTnvType nvoCVOut SNVT_nv_type SNVT_temp Indicates nvoCVOut...

Страница 13: ...nviARMIn SNVT_lev_percent 163 840 163 835 0 0 SNVT_temp 274 0 6279 5 0 0 SNVT_temp_p 273 17 327 66 0 0 SNVT_count_32 0 999 999 999 0 Inputs the value to be compared to the alarm setpoint nvoARM1 SNVT...

Страница 14: ...RMIn SNVT_nv_type SNVT_lev_percent Indicates nviARMIn type For use with LonMaker and other tools SCPTsetpoint 0 nviARMIn SNVT_lev_percent 163 840 163 835 80 000 SNVT_temp 274 0 6279 5 80 0 SNVT_temp_p...

Страница 15: ...viLEDIn02 SNVT_switch nv 99 nviLEDIn03 SNVT_switch nv 112 nviLEDIn16 SNVT_switch Network Variables Configuration Properties Network Variables NETWORK VARIABLE TYPE Range Default EXPLANATIONS nviLEDSta...

Страница 16: ...iables Configuration Properties Extension discrete output Y0 Y2 Y4 Y6 Y8 YA YC YE Output nviDOEX1 status Y1 Y3 Y5 Y7 Y9 YB YD YF Output nviDOEX2 status nv 4 nv 11 nviDOEX1 SNVT_switch nv 12 nv 19 nviD...

Страница 17: ...n or off Y1 Y3 Y5 Y7 Y9 YB YD YF of the extension module depending upon this input 100 0 1 ON Other OFF Configuration Properties CONFIGURATION PROPERTY NETWORK VARIABLE TYPE Range Default EXPLANATIONS...

Страница 18: ...8 XA XC XE X1 X3 X5 X7 X9 XB XD XF Normal Mode Status output at nvoDIEX1 Status output at nvoDIEX2 Combination Mode Refer to the table in the next page fbDIEX SCPTdirection nvoDIEX1 SCPTinvrtOut nvoDI...

Страница 19: ...X6 X8 XA XC XE X1 X3 X5 X7 X9 XB XD XF nvoDIEX1 nvoDIEX2 OFF OFF 0 0 0 OFF Invalid ON OFF 100 0 1 ON Invalid OFF ON 0 0 0 OFF 0 0 0 OFF ON ON 100 0 1 ON 100 0 1 ON nvoDIEX2 SNVT_switch 0 0 0 100 0 1...

Отзывы: