background image

R7L-RS4

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-7804-C  Rev.5  P. 9 / 19

 

FUNCTIONAL BLOCK: fbRS[0...3]

nv 60

...nv 63

nv 64

...nv 67

fbRS [0...3] (Object ID : 25...28)

nvoRSVal
SNVT_temp
SNVT_temp_p

nvoRSPVal
SNVT_lev_percent

Set input sensor type

Network variable type
Deviation temperature to send
Offset adjustment
Gain adjustment
0% and 100% setpoints

Zero adjustment
Span adjustment

fbRS :
     SCPTsceneNmbr
nvoRSVal :
     SCPTnvType
     SCPTminDeltaTemp
     SCPToffset [ ]
     SCPTdefScale
     SCPTsetpoint [ ]
nvoRSPVal
     SCPToffset
     SCPTgain

Network Variables

Configuration Properties

RTD input

Input 0, Input 1, Input 2, Input 3

• Network Variables

NETWORK
VARIABLE

TYPE
{ Range }
{ Default }

EXPLANATIONS

nvoRSVal

{SNVT_temp}
{-274.0...6279.5}
{0.0}
{SNVT_temp_p}
{-273.17...327.66}
{0.0}

Temperature output for Input 0 through 3.

nvoRSPVal

{SNVT_lev_percent}
{-163.840...163.835}
{0.0}

% output proportional to the temperature at Input 0 through 3.

Содержание R7L-RS4

Страница 1: ...POINTS OF CAUTION POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 24V AC rating 24V 10 50 60 Hz approx 85m...

Страница 2: ...ED Used to show network variable status assigned to fbLED ON LED ON OFF LED OFF SERVICE SWITCH Used to identify the node in LONWORKS network configura tion RESET SWITCH Used to reset the Neuron Chip P...

Страница 3: ...mm wide 54 2 13 17 66 4 5 6 7 1 2 3 10 11 12 13 2 3 4 1 15 16 17 18 7 8 9 6 14 5 3 12 5 5 22 50 1 97 18 5 73 115 4 53 7 M3 SCREW TERMINALS for LONWORKS POWER 18 M3 SCREW TERMINALS for INPUT 6 24 6 24...

Страница 4: ...NNECTION HOST PC LONWORKS R7L LONWORKS R7L LONWORKS Terminator WIRING INSTRUCTIONS SCREW TERMINAL Torque 0 5 N m SOLDERLESS TERMINAL Refer to the drawing below for recommended ring tongue terminal siz...

Страница 5: ...g Maximum sending time per fb Minimum sending time per fb Set Tag No name Indicate Model No and Version Indicate Serial No NodeObject Network Variables Configuration Properties Network Variables NETWO...

Страница 6: ...0 0 Maximum time interval to send network variables per fb Power supply must be reset when this configuration prop erty is changed Network variables are sent out in the specified intervals even when...

Страница 7: ...NTOut Set the maximum count Set the value when fbCNT is reset fbCNT SCPTdirection nviCNTIn SCPTinvrtOut nviCNTCtrl SCPTpwrUpState nvoCNTOut SCPTnvType SCPTmaxRnge SCPTsetpoint Network Variables Config...

Страница 8: ...Count always reset to 0 Bit 5 8 through 15 Invalid Minimum input pulse width 500 ms for nviCNTIn 50 ms for the input terminals DO NOT connect a network variable to nviCNTIn when one of the input term...

Страница 9: ...adjustment Gain adjustment 0 and 100 setpoints Zero adjustment Span adjustment fbRS SCPTsceneNmbr nvoRSVal SCPTnvType SCPTminDeltaTemp SCPToffset SCPTdefScale SCPTsetpoint nvoRSPVal SCPToffset SCPTgai...

Страница 10: ...fset 1 SCPToffset 0 SCPTdefScale nvoRSVal SNVT_lev_percent 80 000 120 000 0 0 Gain applied to SCPToffset 0 SCPTsetpoint 0 nvoRSVal Same as nvoRSVal nvoRSVal lower range temperature SCPTsetpoint 0 SCPT...

Страница 11: ...riable type 0 and 100 setpoints Network variable type 0 and 100 setpoints nviCVIn SCPTnumDigits SCPTnvType SCPTsetpoint nvoCVOut SCPTnvType SCPTsetpoint Network Variables Configuration Properties Netw...

Страница 12: ...hat of the source when using 60 63 SCPTnvType nviCVIn SNVT_nv_type SNVT_temp Indicates nviCVIn type For use with LonMaker and other tools SCPTnvType nvoCVOut SNVT_nv_type SNVT_temp Indicates nvoCVOut...

Страница 13: ...nviARMIn SNVT_lev_percent 163 840 163 835 0 0 SNVT_temp 274 0 6279 5 0 0 SNVT_temp_p 273 17 327 66 0 0 SNVT_count_32 0 999 999 999 0 Inputs the value to be compared to the alarm setpoint nvoARM1 SNVT...

Страница 14: ...RMIn SNVT_nv_type SNVT_lev_percent Indicates nviARMIn type For use with LonMaker and other tools SCPTsetpoint 0 nviARMIn SNVT_lev_percent 163 840 163 835 80 000 SNVT_temp 274 0 6279 5 80 0 SNVT_temp_p...

Страница 15: ...viLEDIn02 SNVT_switch nv 99 nviLEDIn03 SNVT_switch nv 112 nviLEDIn16 SNVT_switch Network Variables Configuration Properties Network Variables NETWORK VARIABLE TYPE Range Default EXPLANATIONS nviLEDSta...

Страница 16: ...iables Configuration Properties Extension discrete output Y0 Y2 Y4 Y6 Y8 YA YC YE Output nviDOEX1 status Y1 Y3 Y5 Y7 Y9 YB YD YF Output nviDOEX2 status nv 4 nv 11 nviDOEX1 SNVT_switch nv 12 nv 19 nviD...

Страница 17: ...n or off Y1 Y3 Y5 Y7 Y9 YB YD YF of the extension module depending upon this input 100 0 1 ON Other OFF Configuration Properties CONFIGURATION PROPERTY NETWORK VARIABLE TYPE Range Default EXPLANATIONS...

Страница 18: ...8 XA XC XE X1 X3 X5 X7 X9 XB XD XF Normal Mode Status output at nvoDIEX1 Status output at nvoDIEX2 Combination Mode Refer to the table in the next page fbDIEX SCPTdirection nvoDIEX1 SCPTinvrtOut nvoDI...

Страница 19: ...X6 X8 XA XC XE X1 X3 X5 X7 X9 XB XD XF nvoDIEX1 nvoDIEX2 OFF OFF 0 0 0 OFF Invalid ON OFF 100 0 1 ON Invalid OFF ON 0 0 0 OFF 0 0 0 OFF ON ON 100 0 1 ON 100 0 1 ON nvoDIEX2 SNVT_switch 0 0 0 100 0 1...

Отзывы: