TERMINAL CONNECTIONS

Connect the unit as in the diagram below.

 

EXTERNAL DIMENSIONS  unit: mm (inch)

1

2

3

4

5

6

130 (5.12)

27.5 (1.08)

109 (4.29)

POSITIONING

GUIDE

TERMINAL

COVER

6–M3

SCREW

6.2

(.24)

 

CONNECTION DIAGRAM

1

4

Modbus/TCP RJ-45 MODULAR JACK

INTERNAL BUS

INTERNAL POWER

BUS CONNECTOR

RUN 

+

RUN 

JACK

RUN CONTACT OUTPUT

CONFIGURATION JACK

WIRING INSTRUCTIONS

 

M3 SCREW TERMINAL

Torque: 0.5 N·m

 

SOLDERLESS TERMINAL  unit: mm (inch)

Refer to the drawing below for recommended ring tongue 
terminal size.  Spade tongue type is also applicable.  Solder-
less terminals with insulation sleeve do not fit.
Applicable wire size: 0.75 – 1.25 mm

2

Recommended manufacturer: Japan Solderless Terminal 
MFG. Co.,Ltd., Nichifu Co.,ltd.

3.2 (.13) dia.

4 min.

(.16)

12 (.47) max.

6 max

.

(.24)

3 (.12) max.

Содержание R3-GE1

Страница 1: ...it inside proper housing with sufficient ventilation Do not install the unit where it is subjected to continuous vibration Do not apply physical impact to the unit Environmental temperature must be wi...

Страница 2: ...F OFF OFF 2 ON OFF OFF 3 OFF ON OFF 4 ON ON OFF 5 OFF OFF ON 6 ON OFF ON 7 OFF ON ON 8 ON ON ON LED Function SW3 4 Functions assigned to the front RUN and ERR LEDs can be selected SW3 4 LED FUNCTION R...

Страница 3: ...N DIAGRAM 1 4 Modbus TCP RJ 45 MODULAR JACK INTERNAL BUS INTERNAL POWER BUS CONNECTOR RUN RUN JACK RUN CONTACT OUTPUT CONFIGURATION JACK WIRING INSTRUCTIONS M3 SCREW TERMINAL Torque 0 5 N m SOLDERLESS...

Страница 4: ...ith 32 bytes of data Reply from bytes 32 time 10ms TTL 64 Reply from bytes 32 time 10ms TTL 64 Reply from bytes 32 time 10ms TTL 64 Reply from bytes 32 time 10ms TTL 64 Ping statistics for Packets Sen...

Страница 5: ...ram Controller 14 Poll Controller 15 Force Multiple Coils X Digital output from the slave 16 Preset Multiple Registers X General purpose register within the slave 17 Report Slave ID Slave type RUN sta...

Страница 6: ...17 448 6 449 480 7 481 512 8 Holding Registers 4X 1 16 I Analog Output 1 17 32 2 33 48 3 49 64 4 65 80 5 81 96 6 97 112 7 113 128 8 257 288 F Analog Output 1 289 320 2 321 352 3 353 384 4 385 416 5 41...

Страница 7: ...l bus error occurs and the ERR LED turns on Max 16 real I O modules and virtual modules are available The interface module can not read the data for more than 16 modules WHEN R3 GE1 IS MOUNTED ON SLOT...

Отзывы: