Alarm Output Setting
(ALARM)

Change Setting
(SETTINGS)

Power ON delay time
(POWON DLY)

0 thr. 999 seconds (0)

Latching
(LATCHING)

DISABLE (

*

)

ENABLE

Operating mode
(MODE)

Operatint time
(OFF TIMER)

Display brightness
(BRIGHTNESS)

View type memory 
(MODE)

Recover-to-default time
(TIMER)

*

5. Refer to "ALARM OUTPUT SETTING" in this section.

Backlight
(BACKLIGHT)

AUTO : ON by operation and at alarm
             OFF by timer (

*

)

ON : Continuously ON
OFF : Continuously OFF

My Default View
(DEFAULT)

CURRENT : Save the view on display
CYCLIC : ∑ view auto cyclic switching

DISABLE : No auto recovery (

*

)

1 thr. 999 sec. from last operation

∑1
∑2
∑3
∑4
∑5
∑6

Reset customization
(RESET)

∑ View
Customization
(CUSTOMIZE)

0 : Fastest (

*

)

1 thr. 60 seconds

Display Update 
Rate (UPD RATE)

Choose measurands to be displayed on 
Line 1 thr. Line 4

NO : Cancel
YES : Reset

1 thr. 999 seconds (600)

1 : Dark
2 : Normal (

*

)

3 : Bright

Measurands 

*

5

I1-3
IN  

3P4W  3.00

U12-31
U1N-3N
P
Q
S
PF
F
I1-3 AVG
IN AVG  

3P4W  3.00

P AVG
Q AVG
S AVG
THDI1-3
THDIN  

3P4W  3.00

THDU12-31
THDU1N-3N
UT12-31

High setpoint
(HIGH)

HIGH : 

*

5 (0)

LOW : 

*

5 (0)

Low setpoint
(LOW)

Hysteresis (deadband)
(HYSTERES)

0.0 thr. 99.9% (0.0)

0 thr. 999 seconds (0)

Alarm ON delay time
(ON DELAY)

DISABLE : Disable alarm (

*

)

DISP ONLY : Display only
DOUT1 : Discrete output 1 + display
DOUT2 : Discrete output 2 + display

Alarm output
(OUTPUT)

(

*

) or (  ) : Factory setting

Display Setting
(DISPLAY)

Reset Alarm
(CLR ALARM)

ENABLE (

*

)

DISABLE

Shortcut Menu
(SHORTCUT)

Содержание 54UC

Страница 1: ...TS BEFORE USE 2 POINTS OF CAUTION 2 LIGHTNING SURGE PROTECTION 2 COMPONENT IDENTIFICATION 3 EXTERNAL DIMENSIONS unit mm inch 4 TERMINAL CONNECTIONS 5 WIRING INSTRUCTIONS 7 COMMUNICATION CABLE CONNECTI...

Страница 2: ...110 240V DC rating 99 264V DC 4W GENERAL PRECAUTION Before you remove or mount the unit turn off the power supply and input signal for safety ENVIRONMENT Indoor use Do not install the unit where it i...

Страница 3: ...ut Terminals CC Link Terminals Voltage Input Terminals CONTROL BUTTON OPERATIONS IU PQS MAX E PRG PF THD ENTER ESCAPE E PRG ESCAPE E PRG ESCAPE IU PQS PF THD Hold down IU Hold down Hold down Hold down...

Страница 4: ...60 91 5 3 60 100 3 94 25 98 MOUNTING BRACKET 2 M5 SCREW 2 110 4 33 110 4 33 91 5 3 60 91 5 3 60 115 4 53 25 98 MOUNTING BRACKET 2 M5 SCREW 2 92 92 0 8 3 65 0 3 63 0 8 3 65 0 3 63 Panel thickness 2 to...

Страница 5: ...S 1L 3S 3L 1 source load N 2 2 3 k l K L k l K L P1 P2 P3 1S 1L 3S 3L 1 source load N 2 2 3 P1 P2 P3 1S 1L 1 source load 2 3 u v v u U V V U k l K L P1 P2 P3 1S 1L 1 source load 2 3 k l K L P1 P2 P3 1...

Страница 6: ...oad 2 System Application Single phase 2 wire Three phase 3 wire balanced load Single phase 3 wire Three phase 3 wire unbalanced load 2CT Terminal 1S 1L 3S 3L 1 source load 2 3 k l P1 u v U V P2 u v U...

Страница 7: ...S M3 Screw discrete input discrete output CC Link auxiliary power Torque 0 6 N m M4 Screw voltage input current input Torque 1 4 N m COMMUNICATION CABLE CONNECTION DA DB DG SLD FG MASTER UNIT DA DB DG...

Страница 8: ...s CC Link communication status COM SEGMENT STATUS Turn on Normal communications Blinking ON OFF 1 sec CC Link settings changed Turn off No communication Reading from Writing to 54UC via CC Link In ord...

Страница 9: ...o RX1 RWr0 RWr2 RWr3 Master to Slave 54UC Require Reading Writing RY0 ON ON Slave 54UC to Master Acknowledge Reading Writing RX1 OFF ON RWr0 Register number Register number RWr2 Data to write LSW RWr3...

Страница 10: ...2 at this register When it is set the unit stops counting so that a new count value can be written in the register Be careful to use 2 setting because no counting will be performed if the unit remains...

Страница 11: ...eboot the system Any other values can be written but invalid 5332 Backup restore setting 20002 Backup the present setting 30003 Restore the device with the backup setting data The register is automati...

Страница 12: ...ory setting 1 or 5 A 5603 CT rating Secondary 1 to 5 Factory setting 1 or 5 A 5604 VT rating Primary 50 to 400 000 Voltage V Factory setting 110 V 5606 VT rating Secondary 50 to 500 Voltage V Factory...

Страница 13: ...6113 Discrete output 1 function 0 Undefined 1 Energy count 2 Alarm 6114 Discrete output 1 0 Normally open 1 Normally closed Open at the power OFF regardless of this setting 6115 Discrete input functio...

Страница 14: ...201 EQ Reactive energy high tariff LAG 202 ES Apparent energy high tariff 203 EP Active energy high tariff outgoing 204 EQ Reactive energy high tariff LEAD 205 206 EQ LAG EQ LEAD Reactive energy high...

Страница 15: ...play only 2 Display discrete output 1 3 Display discrete output 2 6384 IN Neutral current Hysteresis deadband 3P4W 3 00 0 to 999 Specified value 0 1 Factory setting 0 10 6385 IN Neutral current ON del...

Страница 16: ...pecified value 0 1 Factory setting 0 10 6417 Q Reactive power ON delay time 0 to 999 Seconds Factory setting 0 Seconds 6419 S Apparent power High setpoint Factory setting 0 VA 6421 S Apparent power Lo...

Страница 17: ...tpoint 3P4W 3 00 Factory setting 0 mA 6455 IN AVG Average demand neutral current Alarm output 3P4W 3 00 0 Disable 1 Display only 2 Display discrete output 1 3 Display discrete output 2 6456 IN AVG Ave...

Страница 18: ...ON delay time 0 to 999 Seconds Factory setting 0 Seconds 6491 THD IN Neutral current total harmonic distortion High setpoint 3P4W 3 00 Factory setting 0 10 6493 THD IN Neutral current total harmonic...

Страница 19: ...e voltages Alarm output 0 Disable 1 Display only 2 Display discrete output 1 3 Display discrete output 2 6520 UT12 thr UT31 Phase angle between phase voltages Hysteresis deadband 0 to 999 Specified va...

Страница 20: ...r 100 0 to 2 000 000 000 Power var Factory setting 1 500 var 6783 Reactive power 0 2 000 000 000 to 2 000 000 000 Power var Factory setting 0 var 6785 Apparent power 100 0 to 2 000 000 000 Power VA Fa...

Страница 21: ...efer to the table below 7398 2 Line 2 Measurand to be assigned Refer to the table below 7399 2 Line 3 Measurand to be assigned Refer to the table below 7400 2 Line 4 Measurand to be assigned Refer to...

Страница 22: ...ANGE Current mA 0 to 2 000 000 000 mA Voltage V 100 0 to 20 000 000 00 V Active power W 2 000 000 000 to 2 000 000 000 W Reactive power var 2 000 000 000 to 2 000 000 000 var Apparent power VA 0 to 2...

Страница 23: ...se 1 Phase voltage Phase 2 Phase voltage Phase 3 V 100 V 100 V 100 53 55 57 P1 P2 P3 Active power Phase 1 Active power Phase 2 Active power Phase 3 W W W 59 61 63 Q1 Q2 Q3 Reactive power Phase 1 React...

Страница 24: ...y low tariff incoming outgoing kvarh 10 193 EP_L Active energy fraction high tariff incoming kWh 10 232 195 EQ_L Reactive energy fraction high tariff LAG kvarh 10 232 197 ES_L Apparent energy fraction...

Страница 25: ...ry 3 mA 307 309 311 I1 AVG 3 I2 AVG 3 I3 AVG 3 Current AVG Line 1 History 3 Current AVG Line 2 History 3 Current AVG Line 3 History 3 mA mA mA 313 IN AVG 3 Neutral current AVG History 3 3P4W 3 00 mA 3...

Страница 26: ...Current total harmonic distortion MAX Line 1 Current total harmonic distortion MAX Line 2 Current total harmonic distortion MAX Line 3 10 10 10 871 THD IN MAX Neutral current total harmonic distortio...

Страница 27: ...pparent power MIN Phase 3 VA VA VA 999 1001 1003 PF1 MIN PF2 MIN PF3 MIN Power factor MIN Phase 1 Power factor MIN Phase 2 Power factor MIN Phase 3 1 10 000 1 10 000 1 10 000 TOTAL HARMONIC DISTORTION...

Страница 28: ...id id id id id id id id id id id id id id id id id 2nd 3rd 4th 5th 6th 7th 8th 9th 10th 11th 12th 13th 14th 15th 16th 17th 18th 19th 20th 21st 22nd 23rd 24th 25th 26th 27th 28th 29th 30th 31st 10 10 1...

Страница 29: ...erations stop while one or more system errors are detected 8004 Reserved 8005 I1 thr I3 Current Alarm Bit assignment as shown below Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 l3 HI l2 HI l1 HI l3 LO l2...

Страница 30: ...placed when the respective values are out of the predetermined ranges 0 in all bits means that no alarm is tripped 8015 IN AVG Average demand neutral current Alarm 3P4W 3 00 Bit assignment as shown b...

Страница 31: ...HI THD U12 HI THD U31 LO THD U23 LO THD U12 LO 1 is placed when the respective values are out of the predetermined ranges 0 in all bits means that no alarm is tripped 8022 THD U1N thr THD U3N Phase vo...

Страница 32: ...xample 0 at parameter number and 1 at Bit 0 of this register address means that I1 value is lower than the low setpoint triggering the alarm If another point within the same parameter number goes into...

Страница 33: ...ower digit 7th character 9607 9608 9609 9610 9611 9612 9613 9614 Tag No Upper digit 2nd character Upper digit 4th character Upper digit 6th character Upper digit 8th character Upper digit 10th charact...

Страница 34: ...lected energy reading N Neutral current THD Selected energy reading 3P4W 3 00 1 2 Delta voltage THD 2 3 Delta voltage THD 3 1 Delta voltage THD Selected energy reading 1 N Phase voltage THD 2 N Phase...

Страница 35: ...Phase 3 27 Power factor Phase 1 28 Power factor Phase 2 29 Power factor Phase 3 30 THD Current Line 1 31 THD Current Line 2 32 THD Current Line 3 33 THD Neutral current 3P4W 3 00 34 THD Delta voltage...

Страница 36: ...rgy low tariff outgoing LAG 118 Reactive energy low tariff outgoing LEAD 119 Energy count time low tariff 210 Reactive energy high tariff incoming 211 Reactive energy high tariff outgoing 212 Active e...

Страница 37: ...Current 9th HD Line 2 Current 10th HD I2 08 10 1049 Line 2 Current 29th HD Line 2 Current 30th HD Line 2 Current 31st HD I2 29 31 I3 through U2N 1 I3 through U2N 1 1168 3 N Phase voltage 2nd HD 3 N P...

Страница 38: ...ead varh 19 L TIMER Energy count time h 0 EP Active energy incoming Wh 1 EQ Reactive energy lag varh 2 ES Apparent energy VAh 3 EP Active energy outgoing Wh 4 EQ Reactive energy lead varh 5 EQ LAG Rea...

Страница 39: ...g primary VT PRI 50 thr 400 000 V 110V VT rating secondary VT SEC 50 thr 500 V 110V AC frequency FREQUENCY U1N Voltage I1 Current Low end cutout current CUTOUT I 0 0 thr 99 9 of the rating 1 0 Low end...

Страница 40: ...ng CC LINK Node address ADDRESS 1 thr 64 1 Baud rate BAUDRATE 156 kbps 625 kbps 2 5 Mbps 5 Mbps 10 Mbps 3 3 In order to make the settings effective turn on the power again or reboot the device or rese...

Страница 41: ...switching DISABLE No auto recovery 1 thr 999 sec from last operation 1 2 3 4 5 6 Reset customization RESET View Customization CUSTOMIZE 0 Fastest 1 thr 60 seconds Display Update Rate UPD RATE Choose...

Страница 42: ...IN Neutral current 3P4W 3 00 0 20 000 A U12 31 Delta voltage Line 1 2 2 3 3 1 0 00 400 000 00 V U1N 3N Phase voltage Phase 1 thr Phase 3 0 00 400 000 00 V P Active power 2 000 000 000 2 000 000 000 W...

Страница 43: ...G EXAMPLES SETTING INPUT CONFIGURATION Input system Three phase 3 wire unbalanced load CT ratio 300 A 5 A VT ratio 6600 V 110 V Input Setting INPUT System configuration SYSTEM 3P3W UB 3 phase 3 wire u...

Страница 44: ...Current range I Minimum value LOWER 150A 5A 0A or Factory setting Maximum value UPPER Voltage range U Minimum value LOWER 9000V 300V 0V Maximum value UPPER Active power range P Minimum value LOWER 1 8...

Страница 45: ...TYPE N O Normally open Alarm Output Setting ALARM Measurands I1 3 High setpoint HIGH 120A 50A Low setpoint LOW Hysteresis deadband HYSTERES 1 0 1 Alarm ON delay time ON DELAY DOUT1 Alarm output OUTPUT...

Страница 46: ...press button MAX press button MAX press button MAX press button MAX press button MAX press press E PRG ESC button 2 seconds or more button press press E PRG ESC button 4 times press button 3 times pr...

Страница 47: ...erence Reset the energy readings all energy and time count to zero Go to RESET ENERGY 5 Average demand data destroyed Average demand data stored in the device are destroyed often due to ex cessive noi...

Отзывы: