FRONT PANEL CONFIGURATION

50

40

30

20

10

0

-10

-20

-30

-40

-50

%

100 SET

2

S

P

Z

1

90

80

70

60

50

40

30

20

10

0

SET (ENTER) Button

Color Setpoint 2 Adj. & Function
Span Adj. & Setting

Decimal Point Position, Moving Average,

Brightness Adj, Factory Setting.

Zero Adj. & Setting
Color Setpoint 1 Adj. & Function

Setting UP Button, Switcing Detailed Settings

Mode & Setting Selector

Setting DOWN Button, Switcing Detailed Settings

Digital Indicator

Setpoint 2 Value

Setpoint 1 Value

PV Indicator

M

Note: Setpoint 1 or 2 provided only for the multi-color bar type.

 ALARM OUTPUT CODE 0: None

• Bar Color Patterns

Pattern 1 (Bar LED color code 1)

orange

orange

green

orange

Input < L

L < Input < H

H < Input

green

red

H

L

Pattern 2 (Bar LED color code 2)

orange

green

green

red

red

red

H

L

50

40

30

20

10

0

-10

-20

-30

-40

-50

%

100 SET

H

S

P

Z

L

90

80

70

60

50

40

30

20

10

0

SET (ENTER) Button

H Setpoint Adj. & Alarm Function
Span Adj. & Setting

Decimal Point Position, Moving Average,

Brightness Adj, Factory Setting.

Zero Adj. & Setting
L Setpoint Adj. & Alarm Function

Setting UP Button, Switcing Detailed Settings

Mode & Setting Selector

Setting DOWN Button, Switcing Detailed Settings

H Setpoint

L Setpoint

PV Indicator

M

50

40

30

20

10

0

-10

-20

-30

-40

-50

%

100 SET

H

S

P

Z

L

90

80

70

60

50

40

30

20

10

0

SET (ENTER) Button

HH Setpoint Adj. & Alarm Function
H Setpoint Adj. & Alarm Function
Span Adj. & Setting

Decimal Point Position, Moving Average,

Brightness Adj, Factory Setting.

Zero Adj. & Setting
L Setpoint Adj. & Alarm Function
LL Setpoint Adj. & Alarm Function

Setting UP Button, Switcing Detailed Settings

Mode & Setting Selector

Setting DOWN Button, Switcing Detailed Settings

HH Setpoint

H Setpoint

L Setpoint

LL Setpoint

PV Indicator

HH

LL

M

 ALARM OUTPUT CODE 2: 2 points

Digital Indicator

 ALARM OUTPUT CODE 4: 4 points

Digital Indicator

°C

°C

°C

°C

°C

°C

Содержание 48NDT

Страница 1: ...fect the protection level of this unit when it is integrated in a panel system The user may have to review the CE requirements in regard to the whole system and employ additional protective measures t...

Страница 2: ...CLUSTERED MOUNTING Not conform to degree of protection IP65 1 0 61 5 min USING BEZELS Bezels are used when the unit needs to be adapted to an ex isting panel cutout It is not required when the panel...

Страница 3: ...to the connection diagram on the side of the unit Attach the CJC sensor together with input wiring to the input terminals The CJC sensor is not interchangeable Do not remove No 2 terminal screw so th...

Страница 4: ...4 9 19 136 5 5 37 144 5 67 8 5 33 10 4 41 7 5 30 136 5 5 37 144 5 67 OPTION F BEZEL 4 CONNECTION DIAGRAM T C comp leadwire T C comp leadwire T C comp leadwire 12 13 14 15 16 12 13 14 15 16 LLa 11 La...

Страница 5: ...orange green green red red red H L 50 40 30 20 10 0 10 20 30 40 50 100 SET H S P Z L 90 80 70 60 50 40 30 20 10 0 SET ENTER Button H Setpoint Adj Alarm Function Span Adj Setting Decimal Point Position...

Страница 6: ...lay for L Setpoint Increase Decrease Complete Digital Indicator SET L LL M Press at once ON Time Delay for LL Setpoint Increase Decrease Complete Digital Indicator SET LL Z M Press at once Zero Adjust...

Страница 7: ...inuous ON state 4 Press UP or DOWN buttons until the bargraph shows 0 and the digital indicator comes to a desired value and press SET DIGITAL INDICATOR ZERO ADJUSTMENT 1 Hold down M for 3 seconds and...

Страница 8: ...1 minute after it has been used to choose a indicator LED programming mode During this period pressing the M button briefly is enough to choose another indicator After 1 minute it turns to deac tivat...

Отзывы: