48NDT

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-9444-A  Rev.9  P. 4 / 8

75 (2.95)

103 (4.06)

10 (.39)

18

(.71)

1

3

5
6
7
8
9

10
11
12
13
14
15
16

16–M3 SCREW

TERMINALS

2–M3 SCREWS

CJC SENSOR

(CJM)

144 (5.67)

137.5 (5.41)

*

1

(.16)

36 (1.42)

31 (1.22)

0.5 (.02)

100 (3.94)

2

4

Rounded corners for the option /D

 

OPTION /D BEZEL

*

3

*

1. Space required when replacing the scale plate.

*

2. Used for the existing panel cutout of M-System 48 Series (38 ×

 

139.5 mm).

*

3. Used for the existing DIN panel cutout (33 × 138 mm)

*

4. Used for the existing panel cutout of Fuji Electric PAJ, PAK, PBA (44 × 138 mm), etc.

 

STANDARD BEZEL

*

2

10.4
(.41)

7.5
(.30)

3.9

(.15)

136.5 (5.37)

144 (5.67)

11.4
(.45)

7.5
(.30)

4.9
(.19)

136.5 (5.37)

144 (5.67)

8.5

(.33)

10.4

(.41)

7.5

(.30)

136.5 (5.37)

144 (5.67)

 

OPTION /F BEZEL

*

4

 

CONNECTION DIAGRAM

+

T/C

comp. leadwire

+

T/C

comp. leadwire

+

T/C

comp. leadwire

12

13

14

15

16

12

13

14

15

16

LLa

11

La

LLb

Lc, LLc

7

8

9

8

9

10

HHa

7

Hc, HHc

HHb

Ha

HH OUTPUT

H OUTPUT

LL OUTPUT

L OUTPUT

■ 

ALARM OUTPUT CODE 2: 2 points

15

16

■ 

ALARM OUTPUT CODE 0: None

■ 

ALARM OUTPUT CODE 4: 4 points

3

2

4

+

CJC

SENSOR

metal leg

model: CJM

*

*

Deleted with B thermocouple

3

2

4

+

CJC

SENSOR

metal leg

model: CJM

*

*

Deleted with B thermocouple

3

2

4

+

CJC

SENSOR

metal leg

model: CJM

*

*

Deleted with B thermocouple

U(+)

V(–)

La

Lb

Lc

Hc

Ha

Hb

H OUTPUT

L OUTPUT

POWER

U(+)

V(–)

POWER

U(+)

V(–)

POWER

• DC Powered

■ 

Relay Protection

• AC Powered

LOAD

Inductive

Load (Coil)

Varistor or

CR Circuit

U

LOAD

Inductive

Load (Coil)

Diode, Varistor or

CR Circuit

Содержание 48NDT

Страница 1: ...fect the protection level of this unit when it is integrated in a panel system The user may have to review the CE requirements in regard to the whole system and employ additional protective measures t...

Страница 2: ...CLUSTERED MOUNTING Not conform to degree of protection IP65 1 0 61 5 min USING BEZELS Bezels are used when the unit needs to be adapted to an ex isting panel cutout It is not required when the panel...

Страница 3: ...to the connection diagram on the side of the unit Attach the CJC sensor together with input wiring to the input terminals The CJC sensor is not interchangeable Do not remove No 2 terminal screw so th...

Страница 4: ...4 9 19 136 5 5 37 144 5 67 8 5 33 10 4 41 7 5 30 136 5 5 37 144 5 67 OPTION F BEZEL 4 CONNECTION DIAGRAM T C comp leadwire T C comp leadwire T C comp leadwire 12 13 14 15 16 12 13 14 15 16 LLa 11 La...

Страница 5: ...orange green green red red red H L 50 40 30 20 10 0 10 20 30 40 50 100 SET H S P Z L 90 80 70 60 50 40 30 20 10 0 SET ENTER Button H Setpoint Adj Alarm Function Span Adj Setting Decimal Point Position...

Страница 6: ...lay for L Setpoint Increase Decrease Complete Digital Indicator SET L LL M Press at once ON Time Delay for LL Setpoint Increase Decrease Complete Digital Indicator SET LL Z M Press at once Zero Adjust...

Страница 7: ...inuous ON state 4 Press UP or DOWN buttons until the bargraph shows 0 and the digital indicator comes to a desired value and press SET DIGITAL INDICATOR ZERO ADJUSTMENT 1 Hold down M for 3 seconds and...

Страница 8: ...1 minute after it has been used to choose a indicator LED programming mode During this period pressing the M button briefly is enough to choose another indicator After 1 minute it turns to deac tivat...

Отзывы: