Instructions for installation and use DIAMOND Gas 550V-DV-850V-DV-1150V

 

    OPEN EN CLOSE THE DOOR

For initial setup, you need to clean the window and clear the fireplace of 
any dust and grease that is left behind. This is also the only maintenance 
action that may be performed on the device by the user.

Thanks to a patented system, the door can be easily opened at an angle of 45° to allow a user-
friendly cleaning of the window

To close, push the door gently (but not to soft) against the hooks. Make sure that all
hooks are hooked

CLOSING

OPEN

Above the glass (below the upper frame) hooks are provided (left, right and center). 
Push it upwards with your fingers. the window can now be opened.

Содержание DIAMOND Gas 550V

Страница 1: ...LUNA GAS DIAMOND GAS 550V 550DV 850V 850DV 1150V 02 2017 Instructions for installation and use DIAMOND Gas 550V DV 850V DV 1150V INSTRUCTIONS FOR INSTALLATION AND USE...

Страница 2: ...Y P O S S I B L E D A M A G E P O O R W O R K I N G A P P L I A N C E S A N D A C C I D E N T A S A R E S U LT O F I N C O R R E C T I N S TA L L AT I O N MAINTENANCE GAS FIREPLACE M DESIGN THE M DES...

Страница 3: ...nnection 9 3 1 5 Modification natural gaz to propane 9 4 INSTALLING THE CHIMNEY 10 13 5 FLAME ADJUSTMENT SETTINGS 13 14 6 INSULATION AND FINISHING 14 7 CONVECTION CURRENT 15 18 8 MOUNTING A 3 SIDED FR...

Страница 4: ...nance action that may be performed on the device by the user Thanks to a patented system the door can be easily opened at an angle of 45 to allow a user friendly cleaning of the window To close push t...

Страница 5: ...order specifications this appliance is designed for natural or propane gas Read the instructions before installing and using this appliance Before installing the appliance please check the local regu...

Страница 6: ...liance must not be placed directly on the floor as you need to allow natural convection The appertures for the air supply IN is situated underneath the appliances Regulating the height of the applianc...

Страница 7: ...T BE INSTALLED WITH THIS NEARBOX FIXED AT THE REAR IT IS MAN DATORY TO UNSCREW THE BATTERY FROM THE REAR PRIOR TO INSTALLATION unscrew 4 screws in the corners key 8 gas connection 1 2 reciever DFGT 03...

Страница 8: ...nnection Valve 1 2 After the NEARBOX has removed from the of the back of the fire you can place it loosely on the ground in proximity to the opening provided in the wall of mantelpiece The device is a...

Страница 9: ...making an earthened 220V socket necessary You should bear in mind that the appliance must be connected to all electrical supplies for the purposes of service It s obligatory to connect an earth curren...

Страница 10: ...ee a good working of the appliance with those Between the external wall of the pipe and the wall or the ceiling you should allow for a clearance of at least 50mm and protection that is suitable agains...

Страница 11: ...s obligatory to use the termination set USSAN with positioning flex 130mm or 100mm This USSAN piece must be sealed at the roof Picture 2 Tab 2 150 min 100 Appliance C min C max Position air inlet 850V...

Страница 12: ...uction usvk 13 on appliance Pic 3 Appliance A min B min B max Position air inlet 850V 550V 1 25m 0 75m Wall Exit A 0 5m 4 850DV 550DV 1 25m 0 75m Wall Exit A 4 1 150V 1 25m Wall Exit A 4 A 200 130 in...

Страница 13: ...air inlet 850V 550V 1 25 m 0 75m A C B A 16m 4 850DV 550DV 1 25 m 0 75m A C 0 5m B A 15m 4 1 150 V 1 25 m A C 0 5m B A 15m 4 200 130 Without reduction Appliance A min B max C min A B C max Position a...

Страница 14: ...t if you do not follow these instructions Errorcode F02 will appear Masonry must be raised around the fireplace Due to the expansion of the fireplace during combustion a gap of at least 5 mm must be p...

Страница 15: ...ided M Design has developed hot air and ambient air outlet grilles available from your dealer see page 16 Outlet grids have two or four hose connections 2 4 hoses on 1 grid The air inlet grilles not t...

Страница 16: ...5 5 Instructions for installation and use DIAMOND Gas 550V DV 850V DV 1150V Design grid outlet with 2 connections Inlet grid convection air 2dm 3 Inlet grid convection air 4dm Design gridl outlet with...

Страница 17: ...ry Mirror Main Outlet Mirror Masonry Masonry Mirror 1 2 1 82 484 82 481 488 DRL 2 488x82 Instructions for installation and use DIAMOND Gas 550V DV 850V DV 1150V Design grid outlet with 2 connections f...

Страница 18: ...ance may not be placed directly on the floor without the feet This is to allow natural convection The appertures for the air supply are situated underneath the aplliance Every opening you make must be...

Страница 19: ...r piece by lift it carefully up Pull out the upper frame and in second way the left and right sideframes Take the left and right side of the 3 sided frame 3 5 7 or 10 cm and slide them in the notches...

Страница 20: ...ance with your order you will have either a set of logs diamond sapphire or white pebbles There is an adequate supply of materials Our appliance is approved with these materials so please do not use o...

Страница 21: ...21 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 11 10 12 3 4 5 8 6 7 9 14 13 LUNA 850 DV GAS Instructions for installation and use DIAMOND Gas 550V DV 850V DV 1150V...

Страница 22: ...LUNA 850 DV GAS Instructions for installation and use DIAMOND Gas 550V DV 850V DV 1150V 22...

Страница 23: ...LUNA 850 V GAS Instructions for installation and use DIAMOND Gas 550V DV 850V DV 1150V 23 For appliance with 2 burner in stairs...

Страница 24: ...1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 LUNA 550 V 550 DV GAS Instructions for installation and use DIAMOND Gas 550V DV 850V DV 1150V 24...

Страница 25: ...1 2 3 4 5 6 7 8 LUNA 550 V 550 DV GAS Instructions for installation and use DIAMOND Gas 550V DV 850V DV 1150V 25...

Страница 26: ...roken or cracked the appliance must not be used until the window has been replaced Contact your M Design reseller 11 Safety dvice and maintenance Have your appliance inspected once a year by a qualifi...

Страница 27: ...consequence of Non respect of the order installation and maintenance instructions Assembly installation or repair by a third party including the buyer Heat cracks which normally occur in the mantel I...

Страница 28: ...ressing the button until 24 00 appears in the top left corner 1 Press several times on until you see bnd on the screen 2 Press shortly on and You see the temperature on the screen Your remote control...

Страница 29: ...r If b 1 appaers press to b0 burner 2 goes out 1 2 1 2 Not available for 700H 550V 1000RD en 1300RD 4 Manual control Triple line burner Start the first burner as in the manual control of single line b...

Страница 30: ...Press 2x on the menu button to see whether the fire is set to 0 of 1 position Shut down fire Switch off WAVE In case you want to go to a thermostatic control you follow the next steps Press 2x the bu...

Страница 31: ...rd delivered with lower lath 35 mm 4th side frame The lower lath retracts 5mm into the covering of the fireplace see X values 30 Masonry the lateral lath exceeds 5 mm from the covering of the fireplac...

Страница 32: ...nce TYPE X Y 850 V DV 773 666 550 V DV 473 906 1 150 V 1073 698 X inside frame measurment visible dimension Y Measured from side down of the lower lath to side up of the upper lath Instructions for in...

Страница 33: ...tallation and use DIAMOND Gas 550V DV 850V DV 1150V 14 2 Finishing with 4 sided frame Inlet convection air MANDATORY 1 at the left andright side Opening to provide L X 4mm 4mm 2mm 2mm H Y 2mm 4 sided...

Страница 34: ...kader cadre frame Rahme Luna Diamond 850 V Gas Gaz 32 28 102 98 666 666 666 5 991 23 864 484 176 455 Min 35 mm Max 450 mm 773 int 130 200 4 x 150 131 119 208 666 ext 137 188 656 int 27 32 330 786 5 6...

Страница 35: ...e frame Rahme 10 5 cm kader cadre frame Rahme Luna Diamond 850 DV Gas Gaz 67 63 102 98 32 28 5 468 522 662 592 27 5 32 363 786 1016 23 Min 35 mm Max 450 mm 909 229 458 162 666 ext 188 522 130 200 164...

Страница 36: ...kader cadre frame Rahme 10 5 cm kader cadre frame Rahme Luna Diamond 550 V Gas Gaz 32 28 102 98 473 int 896 int 906 ext 32 1252 23 158 188 455 176 484 130 200 137 330 565 Min 35mm Max 450mm 329 486 2...

Страница 37: ...cadre frame Rahme 10 5 cm kader cadre frame Rahme Luna Diamond 550 DV Gas Gaz 906 906 32 28 5 67 63 102 98 468 522 592 662 229 458 522 130 200 119 109 240 4 x 150 609 1256 23 Min 35 mm Max 450 mm 363...

Страница 38: ...r cadre frame Rahme 10 5 cm kader cadre frame Rahme Luna Diamond 1150 V Gas Gaz 32 28 102 98 706 706 706 5 484 130 200 176 455 1073 int 696 int 706 ext 137 138 27 32 330 1086 Min 35 mm Max 450 mm 981...

Страница 39: ...39 Instructions for installation and use DIAMOND Gas 550V DV 850V DV 1150V 16 Identification boards...

Страница 40: ...40 Instructions for installation and use DIAMOND Gas 550V DV 850V DV 1150V...

Страница 41: ...41 Instructions for installation and use DIAMOND Gas 550V DV 850V DV 1150V 17 CE Certification...

Страница 42: ...42 Instructions for installation and use DIAMOND Gas 550V DV 850V DV 1150V...

Страница 43: ...43 Instructions for installation and use DIAMOND Gas 550V DV 850V DV 1150V...

Отзывы: