Instructions for installation and use of ARGENTO
- 8 -
5.3.
C
HIMNEY
The construction of chimney must comply with strict conditions:
The flue must be thermally insulated. The opening into the flue and its
position are very important.
One individual flue does not have more than two changes of direction. The
angle of the corner of these changes of direction may not be greater than
45 ° with the perpendicular.
The existing obstacles in the vicinity of the opening into the flue must be
taken into account.
Do not connect more than one stove to a chimney.
All the Argento stoves have a standard flue opening of 200mm or 250 mm. in
diameter. Certain chimney configurations may require different standard
diameters. In that case, look at table for the height of the flue and the
possibility of reducing the diameter with the help of a reduction piece.
Chimney connection is situated on the top of device.
When the door is closed there is slow directed flue flow to the chimney in
combustion chamber. Valve for short cut is opened and closed according door
movements. It is automatically opened when the window is slid open, so that no
smoke escapes into the living room.
Note: per 45° change of direction, one must keep to within 1m of this table.
Minimum height of the chimney in terms of its reduction
Ø250
Ø200
Ø180
Argento 750 H
>4m
>7m
Argento 900 H
≥4m
>4m
>7m
Argento 1050 H
≥4m
>5m
Argento 1200 H
≥4m
>6m
Argento 1350 H
≥5m
>8m
Argento 900 V
≥4m
>7m
Argento 1050 V
≥4m
>8m
5.4.
A
IR SUPPLY REGULATION
The air supply to the Argento can be regulated manually. Use the key (Pic.15)
to slide the regulator to the left to close primary and secondary air and on
the right for opening primary and secondary air. When door is open this
regulation will not have an effect on the fire.
Pic.15
5.5.
INSTALLATION AND REMOVAL OF LABYRINTH DEFLECTOR
1
2
3
4
5
6
7
8
Pic.14
min