Instructions for installation and use of ARGENTO
- 10 -
6.4.
S
PECIFICATIONS AND IDENTIFICATION BOARDS
TYP- ARGENTO
750 H 900 H,V 1150 H,V
1200H
1350H
Nominal heat output (kW)
9
10
11
12
13
The average efficiency (%)
78
78
78
78
78
Heat flow to the space
(kW)
9
10
11
12
13
Output range (kW)
3 - 11 3,5 - 12
4 - 13
5-13
6-14
Flue gas temperature by
nominal output (°C)
190
190
195
195
195
Average concentration of CO
counted on 13% O2 (%)
0,12
0,12
0,12
0,12
0,12
Average volume concentration
of CO counted on 13% O2
(mg.m-3)
1540
1540
1540
1540
1540
Minimum chimney draft (Pa)
12
12
12
12
12
Weight (kg)
240
260
280
300
320
Minimum distance from
flammable materials from the
side and from the back (mm)
300
300
300
300
300
Minimum distance from
flammable materials from the
glass side (mm)
1000
1000
1000
1000
1000
Fuel supply interval (hour)
1
1
1
1
1
Recommended fuel -
dry
wood
beech, oak, spruce
Consumption of wood at
nominal output (kg/h)
3,2
3,5
3,7
3,9
4,1