background image

Instructions for installation and use of ARGENTO 

- 6 - 

5.

 

CONVECTION

 

CURRENT

 

 

5.1.

 

NATURAL CONVECTION AND HOT AIR DUCTS

 

Please follow the installation guide. The appliance can overheat if 
you not apply those instructions. 

 

It is compulsory to open hot air vents at the top of the appliance  (Pic.13/1). 
The entrances for the air supply convection are situated on the bottom side of 
the Argento (Pic.13/2) and also through the opening that is provided for the 
fan.  

 

  

 

 

The device is placed at least 20 mm above the floor (if placed on the floor) to 
allow for natural convection. 
A clearance of at least 4 dm

3

, excluding the measurements of a dust filter, or 

at least 6 dm

3

, including the measurements of a filter, must be provided for in 

the masonry.  
The  enclosure  of  the  appliance  must  be  provided  with  ventilation  grills  or 
openings  allowing  for  the  elimination  of  heat  by  convection.  It  is  possible  to 
have  a  convection  kit  fitted  with  the  appliance.  This  system  directs  the  heat 
inside the room by means of flexible tubes (dia. 150 mm).  
Thermally  insulated  ducts  are  essential  for  the  optimal  functioning  of  the 
appliance  (these  cause  ‘draught’  in  the  convection  air  current).  By  using  the 
maximum  number  of  ducts  (at  least  2),  the  output  is  improved  and  the  noise 
(that is caused by the displacement) is reduced. 
For  the  purposes  of  the  installation  of  these  ducts  it  is  best  to  go  vertically 
upwards  first for at least 1m  and  then  to change direction, making a rather 
wide  bend  and  avoid  using  a  flue  terminal  grid  with  a  small  clearance 
because  the  speed  loss  that  this  causes  reduces  the  efficiency  of  the  hot  air 
vents.  

Place all the fittings that you use at the same lengths and angles if possible, 
otherwise some grids could give off more heat than others and, seeing that a 
hot air pipe functions in a manner similar to a chimney, the one that is hot first 
has the most draught and therefore becomes hot even more quickly.  

 

Note: 

A circulation of hot air requires that no under-pressure be created in the 

room.  A  grid  that  is  near  the  floor  sees  to  it  that  cold  air  can  be  drawn  in. 
Don’t  connect  those  with  a  flexible.  Air  will  find  the  way  to  get  at  the  right 
place. 
M-design has developed its ideal hot air grids which have many advantages 
(Pic. next page) and for the elimination of hot air and the entry of warm air 
we advise you to use these Design grills made by  M-Design. To simplify the 
mounting of the grids you can use the corner profile which is furnished with the 
grid. This profile can be mounted on the side of the grid (two little wholes and 
screws are provided). 

 

ATTENTION:  A  house  is  never  completely  100  %  dustfree,  heating  appliances  and 
warmth circulation creates dust particles. During the periods where you are not using 
the fireplace, dust is accumulated in the flexible pipe and the grills. This could cause a 
problem with a smell, so we would certainly advise you to clear the flexible and air 
inlets  and  outlets  using  a  vacuum  cleaner  regularly.  The  smell  caused  by  these  dust 
particles  will  disappear  after  you  have  used  the  fireplace  again  a  few  times.  This 
phenomenon  is  very  common  and  can  be  compared  to  the  gray  traces  appearing 
above your radiators. Optionally you can order design metal lids to cover the inlets 
and outlets during the summertime. 

 

5.2.

 

F

AN

 

Installation: 

 

Remove the Chamotflex plates, the bottom plates and the opening to the fan.  

 

Now slide the fan downwards to just under the stove. 

 

Make the necessary electrical connections. 

Fan dimmer: 

 

Leave the adjustment of the fan speed closed. 

 

Fuse  1.5A  (Take  the  knob  off,  unscrew  the  little  plate,  take  it  out  if  it  is 
needed to be replaced.) 

 

The adjustment screw for the minimum speed is under the knob. (M-design has 
developed  a  new  induction  dimmer  which  lets  the  fan  run  noiselessly  and 
which may be bought as an option.) 

 

The fan (optional) may be started after the fire has burned for 15 minutes. 

 

Let the fan turn at the maximum speed for 12 hours the first time to let it run 
in. 

 

Pic.13 

Содержание ARGENTO 1050 H

Страница 1: ...Instructions for installation and use of ARGENTO 1 ARGENTO H V Instructions for installation and use ...

Страница 2: ...TH DEFLECTOR 8 6 GENERAL RECOMMENDATIONS 9 6 1 MAINTENANCE 9 6 2 CLEANING THE WINDOW 9 6 3 SUPPLIED ACCESSORIES 9 6 4 SPECIFICATIONS AND IDENTIFICATION BOARDS 10 7 TECHNICAL DRAWING 11 8 SPARE PARTS 17 9 GUARANTEE 18 9 1 TERMS AND ITEMS 18 9 2 PROVISO 18 9 3 DISCLAIMER 18 1 GENERAL 1 1 TRANSPORT AND INSTALLATION Transport the Argento in an upright position or in encumbering circumstances at an ang...

Страница 3: ...of wood in the stove and light the tinder Leave the door slightly open 3 cm to get a turbo stream of air that will make the some kindling catch fire After the kindling have caught fire and burn well the logs may be placed on the fire After the logs have caught fire the door may be shut NOTE When a fire is made for the first time the paint will harden and that give off smoke and a smell which start...

Страница 4: ...place insert must be from non combustible material at least 100 cm in front of the front wall of the fireplace insert The device must be installed so that the front of it remained free space on a minimum ground plan of about 1 x 1 m Place the appliance on a stable surface using the adjustable feet Adjust the height of the appliance turning the bolt THE STOVE MAY NOT BE PLACED DIRECT ON THE FLOOR T...

Страница 5: ...nds to be very warm Please check that the furnace is not fitted too narrow and that there is adequate space for the elimination of hot air For insulation of the furnace we advise you to use M Design insulating plates You are advised against using any other insulation product Inflammable materials as well may not be used for the finishing The masonry must be raised around the furnace Because of the...

Страница 6: ...ore becomes hot even more quickly Note A circulation of hot air requires that no under pressure be created in the room A grid that is near the floor sees to it that cold air can be drawn in Don t connect those with a flexible Air will find the way to get at the right place M design has developed its ideal hot air grids which have many advantages Pic next page and for the elimination of hot air and...

Страница 7: ...Instructions for installation and use of ARGENTO 7 EACH APPERTURE YOU MAKE MUST BE CONNECTED WITH FLEXIBLE ...

Страница 8: ...of a reduction piece Chimney connection is situated on the top of device When the door is closed there is slow directed flue flow to the chimney in combustion chamber Valve for short cut is opened and closed according door movements It is automatically opened when the window is slid open so that no smoke escapes into the living room Note per 45 change of direction one must keep to within 1m of thi...

Страница 9: ...move the remainder of the ash in time take the ash pan and remove a great part of the ashes from the Argento Note Never remove all the ashes because a fire always burns better with its own ashes Cleaning of labyrinth deflector Before 11 2015 Fold out the deflector 1 toward soot will fell down This cleaning is necessary to do once a month during winter heating season In case if you don t clean it t...

Страница 10: ...5 195 Average concentration of CO counted on 13 O2 0 12 0 12 0 12 0 12 0 12 Average volume concentration of CO counted on 13 O2 mg m 3 1540 1540 1540 1540 1540 Minimum chimney draft Pa 12 12 12 12 12 Weight kg 240 260 280 300 320 Minimum distance from flammable materials from the side and from the back mm 300 300 300 300 300 Minimum distance from flammable materials from the glass side mm 1000 100...

Страница 11: ...Instructions for installation and use of ARGENTO 11 7 TECHNICAL DRAWING Without convection chamber ARGENTO 750 H BASIC 210 kg With convection chamber ARGENTO 750 H PREMIUM 225 kg ...

Страница 12: ...Instructions for installation and use of ARGENTO 12 Without convection chamber ARGENTO 900 H BASIC 230 kg With convection chamber ARGENTO 900 H PREMIUM 260 kg ...

Страница 13: ...Instructions for installation and use of ARGENTO 13 Without convection chamber ARGENTO 900 V BASIC 260 kg With convection chamber ARGENTO 900 V PREMIUM 290 kg ...

Страница 14: ...Instructions for installation and use of ARGENTO 14 Without convection chamber ARGENTO 1050 H BASIC 260 kg With convection chamber ARGENTO 1050 H PREMIUM 290 kg ...

Страница 15: ...Instructions for installation and use of ARGENTO 15 Without convection chamber ARGENTO 1050 V BASIC 310 kg With convection chamber ARGENTO 1050 V PREMIUM 340 kg ...

Страница 16: ...Instructions for installation and use of ARGENTO 16 Without convection chamber ARGENTO 1200 H BASIC 290 kg With convection chamber ARGENTO 1200 H PREMIUM 320 kg ...

Страница 17: ...Instructions for installation and use of ARGENTO 17 8 SPARE PARTS ...

Страница 18: ...of the order installation and maintenance instructions 3 Chimney draught that has not been adjusted 4 Transport and installation 5 Incorrect usage 6 Insufficient maintenance 7 Unsuitable hazardous and damp fuel Every internal adjustment to or reconstruction of the stove by third party including the buyer 8 Burning at extremely high temperature more than 12 kW 9 Costs for packaging and transport 10...

Отзывы: