JS-MD 3 RES
Flight Manual Supplement
MD11-AFM-00-002
Issue: 02
Rev. 00
Rev. Date: 24-Mar-23
Page 3
–4
Verify propeller aligns vertically (via the screen graphics and
the rear-view mirror) after reducing power to 0%.
If the propeller does not align vertically, momentarily apply
power, and check propeller again to verify vertical alignment.
Verify that cooling fans are activated at a controller temperature
of 40˚C (104 ˚F) or higher.
Perform extension and retraction of the pylon using MANUAL
mode.
NOTE:
MANUAL mode is entered from AUTO mode by simply
pressing the EXT/RETR toggle switch in the opposite
direction of travel.
If the pylon is extending in AUTO mode, press the
EXT/RETR toggle switch downwards once
– pylon
movement will immediately pause and the DCU will
automatically change to MANUAL mode.
If the pylon is retracting in AUTO mode, press the
EXT/RETR toggle switch upwards once
– the pylon
movement will immediately pause and the DCU will
automatically change to MANUAL mode.
CAUTION:
Always disarm the propulsion system by turning off the
guarded RES master switch prior to any bystanders
approaching. Circuit breakers of the 12 V battery
supply batteries may also be pulled if leaving the
aircraft unattended.
CAUTION:
Applying full power on the ground may produce enough
pitch-down moment from the pylon to push the
aircraft
’s nose to the ground. Apply only enough power
during the stationary ground run to verify proper RES
function.
CAUTION:
Ensure the propeller blast will not impinge or blow dust
towards other aircraft, equipment, persons, or
structures.