JS-MD 3 RES
Flight Manual Supplement
MD11-AFM-00-002
Issue: 02
Rev. 00
Rev. Date: 24-Mar-23
Page 10
–2
No Data from Battery B
No CAN message from right battery.
Watchdog Reset
Software error detected. DCU restarted
automatically.
No Communication
CAN-Bus Fault. Check wiring.
Supply Voltage Low.
Start recharging
supply voltage battery
The supply voltage is below 10.0 V. Switch on the
recharging process via the System Screen.
Retraction
Mechanism Error!
Possible causes:
•
Current to spindle exceeds OEM-adjustable
limit.
•
The spindle is switched on but there is no
feedback.→
The spindle seems to be
blocked.
Retraction Mechanism Timeout!
Spindle blocked?
Spindle was powered for more seconds that OEM
Adjustable limit.
Precharge Timeout!
Service Disconnect?
Voltage on high voltage rail does not reach battery
voltage in time. Main relay cannot be closed.
MC: BAD PARAMETER
Damaged Parameter
MC: POWER FAULT
Overall message of hardware monitoring 1
MC: RFE FAULT
Safety circuit faulty (only active with RUN)
MC: BUS TIMEOUT
CAN-Bus timeout
MC: FEEDBACK
Resolver signal faulty or missing
MC: POWER VOLTAGE
Power voltage missing
MC: MOTOR TEMP
Reduce Power Instantly!
Motor temperature too high (> 115 °C)
MC: DEVICE TEMP
Device temperature too high (> 80°C)