JS-MD 3 RES
Flight Manual Supplement
MD11-AFM-00-002
Issue: 02
Rev. 00
Rev. Date: 24-Mar-23
Page 10
–5
Communication Timeout
seconds.
CAUTIONS
Retraction Mechanism
not calibrated.
Service Screen!
Pylon angle does not correspond to spindle current
or pylon angle values are not valid.
Interlock Warning!
Battery or Charger not Connected!
Connectors not fully closed.
Battery A not Connected
DCU does not get any data from Battery A
Battery B not Connected
DCU does not get any data from Battery B.
All Batteries low !
Remaining motor operation time < 5 minutes.
Battery voltage difference too high.
NO TAKE-OFF !!!
Battery voltage difference is > 30 V. Battery with
lower voltage is disabled, so no take-off is
possible.
Battery Cell Voltage Low
Motor LIMITED !
At least one battery cell voltage gets down to the
low level.
Remove Charger !
If in standby motor operation is demanded but the
charger is still connected.
Motor Current Limit!
Temperature Motor Controller
Motor controller limits power to the motor.
This message shouldn’t show up in a system with
correct parameter setup
Motor Current Limit!\
Motor Temperature
Motor controller limits power to the motor.
This messag
e shouldn’t show up in a system with
correct parameter setup
Motor Current Limit!
Propeller Speed limit
Motor controller limits power to the motor.
This message shouldn’t show up in a system with
correct parameter setup
Supply Voltage Low.
Recharge supply voltage battery
Supply voltage below 10,5 V
Insulation Resistance low.
Check Insulation!
Insulation resistance between HV-rail and supply
voltage r
ail below 200kΩ.
One Battery disconnected
NO TAKE-OFF !!!
One battery operation. Battery power is limited to
about 19 kW, so no take-off is possible.