User Guide
14
DCP-200
Method 2: Factory Reset
Performing a Factory Reset will clear all battery backed memory and restore all functions to their
factory defaults, just like they were when you used DCP-200 for the fi rst time. Please note that anything
you have recorded in the Song Recorder will be erased by this procedure!
‣
To do a Factory Reset:
Turn the Power Off.
Hold down the Reverb and Voice/Function buttons while powering
on DCP-200.
The LED Display will light ALL segments, and all LEDs on the device will light while these
buttons are held down. Once this has happened, you can release the Reverb and
Voice/Function buttons.
When the Reverb and Voice/Function buttons are released, DCP-200 will return to
Performance Mode (ready-to-play). All button LEDs will return to their default states. The LED
Display will show the version number of the fi rmware (the piano’s internal operating software)
for 2 seconds and then return to showing the Voice Name (Grand Piano - Pno).
DCP-200 will then function normally and as if powered on for the fi rst time.
2
1
ON / OFF
Reverb
Song
RECORD
Data Control
[Assignable]
Metronome
Voice / —
Function
-r-
MASTER VOLUME
+
ON / OFF
Содержание DCP-200