MM-010539-001, Rev. P6G
48
6.
Prepare the Client DC cable by cutting excess length
from both wires and stripping the ends. Leave enough
wire length for service loops.
7.
Connect the red wire to the wire-clamp on the Fuse
Block’s load-side wire-clamp.
8.
Connect the black wire to the wire-clamps on the
Grounding Block.
9.
Install a 2AMP ATC automotive fuse into the Fuse
Block.
10.
Tie and stow all cables and wires as necessary so they
remain out of the way of casual contact, and so wire
chafe is avoided.
11.
Apply the sticker included in the Fuse Distribution Rail Kit in the vicinity of the Fuse Block as future
reference for service personnel.
CAUTION
Installing a fuse with the wrong current rating could cause an unsafe condition and/or a
prematurely blown fuse. Verify the correct fuse value for the device being installed.
8.4 GROUNDING
STUDS
Mounting studs for grounding the Client are located on two sides of the Client. While these studs are
primarily used for grounding in Fixed Station installations, it is recommended to run a ground strap from
one of the two ground studs to a nearby chassis ground.
CAUTION
DO NOT connect the Return (PWR-) connection directly to the negative battery post.
In the event the negative battery post wiring becomes disconnected from the chassis,
this would cause all vehicle current to source back through the Client connection to
ground, thus causing damage to the client.
8.5 NETWORK/DATA
CONNECTION
The Standard Client in a mobile configuration connects to the network using a standard Ethernet RJ-45
protocol. The DATA connector is a Tyco/Electronics, Industrial Circular Ethernet Connector
Part number: 1738607-2, an industrial grade, rugged, UV rated, weatherproof, dustproof and made for
use in extreme electrical and climatic conditions. The connector meets IP67 industrial standard for
weatherproof and dustproof electrical connections. Refer to Section 11.1 for cable/connection installation
instructions.
The service port has a dust cap which is normally installed to provide sealing when not in use. Sealing of
all other ports on the Client is provided through mandatory usage connections.
DC Power Cable’s
red power wire
(to Client)
DC Power Cable’s
black ground wire
(to Client)
Fuse Blown
Indicator Light (on
input
side of ATC
Fuse)