background image

Photo 3. Suction and pumping device 1.5 kW, 230 V

 

Slow-speed pumps: 

Code of the 
pump 

Suction and pumping  device for creaming and 
pumping of honey 

W2021GNF 

0.37 kW, 230V - range from 0 to 360 rpm 

(speed adjustment with the help of knob)

 

W20210GNF  1.5 kW, 230V - ranges from 0 to 560 rpm 

(speed adjustment with the help of a knob)

 

Suction and pumping devices - for forcing through, pumping 
honey. Rotor housing made of stainless steel with elastomer 
rotor.

 

5. Technical parameters of devices:

Suction and pumping  pumps  to honey are divided into two 
types:

 

Suction and pumping devices 0.37kW:

- power 0.37 kW
-

optimum performance 900l/h, at a temperature of 30° C for

honey
- power supply 400V
- gear-motor
- after applying the inverter, power supply for 230V with
smooth adjustment.

Suction and pumping devices 1.5kW:

- power 1.5 kW
-

optimum performance 1500 l/h, at a temperature of 30° C

for honey
- power supply 400V
- gear-motor
- after applying the inverter, power supply for 230V with
smooth adjustment.

Both types of suction and pumping devices are equipped 
with road wheels and a handle for easy changing the 
position of suction and pumping device.

6. Error codes

STOP

2 Hz

E-000

INTERNAL DEFECT OF THE MICROPROCESSOR 

CONTROLLER 

STOP

2 Hz

E-001

PRESSED / LOCKED THE START BUTTON 

DIRECTION - LEFT

STOP

2 Hz

E-002

PRESSED / LOCKED THE STOP  BUTTON 

STOP

2 Hz

E-003

PRESSED / LOCKED THE START BUTTON 

DIRECTION - RIGHT 

STOP

2 Hz

E-004

ERROR OF THE ALARM LOOP - EMERGENCY BUTTON 

PRESSED 

Содержание w2021GNF

Страница 1: ...rstwo Pszczelarskie Apiarian Enterprise Thomas yso Limited liability company limited partnership Rac awicka Str No 162 PL 34125 Su kowice Poland www lyson com pl email lyson lyson com pl phone 48 33 8...

Страница 2: ...erational safety 2 The use of suction and pumping devices 3 Work commencement with suction and pumping device 3 1 Preparation of the device to operation 4 Characterization of suction and pumping devic...

Страница 3: ...or mental capabilities or lack of experience and knowledge concerning the equipment unless this is done under the supervision or in accordance with the instructions for use of the equipment handed ove...

Страница 4: ...th outlets of the rotor we connect conduits put the hose Correct fastening the hose We unbuckle the tip end for the hose We slide the end tip into the hose and firmly clamp band clip We prepare the ho...

Страница 5: ...pumping We stop the pump by turning the switch to the stop position that is 0 Before pumping one should check the direction of pumping Photo 1 Suction and pumping device 0 37 kW 1 5 kW 400 V Code of t...

Страница 6: ...a temperature of 30 C for honey power supply 400V gear motor after applying the inverter power supply for 230V with smooth adjustment Suction and pumping devices 1 5kW power 1 5 kW optimum performanc...

Страница 7: ...f the work the pump must be thoroughly cleaned and dried Before each new season one should make an additional technical review and in the event of fault detection please contact the service centre The...

Отзывы: